Caution!
Compliance with EN50130-4 Alarm Standard – CCTV for Security Applications
To meet the requirements of the EN50130-4 Alarm Standard, an ancillary uninterruptable
power (UPS) supply is necessary. The UPS must have a Transfer Time between 2–6 ms and a
Backup Runtime of greater than 5 seconds for the power level as specified on the product
datasheet.
Ethernet Connections
!
Caution!
Ethernet cables must be routed through earth-grounded conduit capable of withstanding the
outdoor environment.
Note: Consult the National Electrical Code (NEC) for cable bundling requirements and
limitations.
Cable Type
Cat5e/Cat6e Ethernet (directly to the camera, or to a network switch
between the camera and the network)
Maximum Distance
100 m (330 ft)
Bandwidth
10BASE-T/100BASE-TX, auto-sensing, half/full duplex
High PoE (95W required for models
with illuminators)
Use the 95 W midspan sold by Bosch.
High PoE (60W only for models
without illuminators)
Use the 60 W midspan sold by Bosch, or a midspan that is compliant to the
IEEE 802.3at, class 4 standard.