Error
Name
Description
Error 01
Invalid Camera Request
The camera number entered from the keyboard does not exist. If
using the optional LTC 8059/00 Master Control Software or the LTC
8850/00 Graphical User Interface Software, ensure that the number
exists in the Camera Identification table. Download the table to be
sure.
Error 02
Invalid Monitor Request
The monitor number entered from the keyboard does not exist.
Error 03
Remote Device Locked by User#
The remote device requested cannot be controlled, because it is
locked by a user with equal or higher priority. Check with the other
users or request that a higher priority user unlock the remote
device.
Error 04
Monitor Locked by User#
The monitor requested cannot be accessed, because it is locked by
a user with equal or higher priority. Check with the other users or
request that a higher priority user unlock the monitor.
Error 05
Remote Device Access Restricted
Remote locked out by Remote Lock Out table.
Error 06
Monitor Access Restricted
Monitor locked out by Monitor Lock Out table.
Error 10
Access Denied
A function was requested for which the user priority is too low. Only
a Priority 2 user or a supervisor with Priority 1 may access this
function.
Error 11
Access Denied
A function was requested for which the user priority is too low. Only
a supervisor with Priority 1 may access this function.
Error 15
Invalid User Function
The function number requested from the keyboard is invalid. Refer
to the User Function table for a listing of valid user function
numbers.
Error 20
Acknowledge Denied
The ACKNOWLEDGE button was pressed by a user without the
authority to acknowledge alarms.
Error 21
Incorrect Acknowledge
In order to properly acknowledge an alarm event, the keyboard
must be switched to a monitor that is displaying the alarms.
Error 22
Acknowledge Disabled
Alarms on this monitor cannot be acknowledged, because that
capability has been disabled by the system programmer.
Error 23
Camera not in Alarm
The camera displayed on the monitor is not an alarm video; only
alarm-generated video can be acknowledged.
Error 24
Keyboard Not Enabled for
Acknowledge
This keyboard may not acknowledge alarm video on this monitor; it
has been disabled by the system programmer.
Error 25
Alarm Switcher Running
Alarm video may only be acknowledged if the alarm switcher is not
running; press HOLD to stop the switcher.
Error 50
Sequence Not Available
The user attempted to load a switcher sequence that does not exist.
This is a good way to determine, from the keyboard, which
sequence numbers are unused when desiring to add one. A request
was made to load an ABSOLUTE type sequence, without the
keyboard being on one of the monitors in that sequence. Because
inadvertent loading of monitors should be avoided, the user is
required to switch his keyboard to one of the monitors used by the
sequence. The PROGRAM mode may be used to review which
monitors are used in the sequence.
Error 52
Sequence Request
A request was made to load a RELATIVE type sequence on a monitor
number that is too high; the monitors used by the sequence would
extend past the highest monitor. Try switching to a lower monitor
number before loading the sequence.
Summary of Contents for IntuiKey Series
Page 1: ...IntuiKey Keyboard Keyboard Version 1 93 en User Manual ...
Page 2: ......
Page 40: ...36 en IntuiKey Keyboard F 01U 127 291 1 93 2009 03 User Manual Bosch Security System Inc ...
Page 44: ...40 en IntuiKey Keyboard F 01U 127 291 1 93 2009 03 User Manual Bosch Security System Inc ...
Page 48: ...44 en IntuiKey Keyboard F 01U 127 291 1 93 2009 03 User Manual Bosch Security System Inc ...
Page 49: ......