INTEGRUS | Digital Infra-red Language Distribution System
en |
19
BOSCH Security Systems | February 2003
R2
R1
R4
R6
R9
20m
R7
R5
R10
Tx2
R8
R3
Tx1
20m
30m
20m
50m
30m
20m
20m
30m
30m
20m
Figure 1.28 System with master and slave transmitter in multi purpose room
Table 1.3 Calculation of the master-to-slave signal delays
Cable length
master-slave
transmitter [m]
Cable
signal delay
per meter [ns/m]
Cable
signal delay
[ns]
Signal delay
slave transmitter
[ns]
Master-to-slave
signal delay [ns]
50
5.6
50 x 5.6 = 280
33
280 + 33 = 313
Table 1.4 Calculation of the delay switch positions of a system with two transmitters
Radiator
number
Transmitter
Master-to-
slave signal
delay [ns]
Cable signal
delay [ns]
Total signal
delay [ns]
Signal delay
difference
[ns]
Delay switch
position
1
Master
0
168
0+168 = 168
593
-168 = 425
425/33 = 12.88 = 13
2
Master
0
280
0+280 = 280
593
-280 = 313
313/33 = 9.48 = 9
3
Master
0
112
0+112 = 112
593
-112 = 481
481/33 = 14.58 = 15
4
Master
0
168
0+168 = 168
593
-168 = 425
425/33 = 12.88 = 13
5
Master
0
280
0+280 = 280
593
-280 = 313
313/33 = 9.48 = 9
6
Slave
313
168
313+168 = 481
593
-481 = 112
112/33 = 3.39 = 3
7 Slave 313
280 313+280
=
593
593
-593 = 0
0/33 = 0
8
Slave
313
112
313+112 = 425
593
-425 = 168
168/33 = 5.09 = 5
9
Slave
313
168
313+168 = 481
593
-481 = 112
112/33 = 3.39 = 3
10 Slave 313
280 313+280
=
593
593
-593 = 0
0/33 = 0