2.5.13 Configure auxiliary inputs
The way the signals on the auxiliary inputs (Aux-.L and Aux.-R) are handled can be set in the Aux. Input Mode menu (4H).
When the option 'Stereo' is chosen, the signals on both Aux. inputs are distributed as a stereo signal to all channels. This setting
can for instance be used to transmit a music signal during breaks in a conference. Note that the Transmission mode must be set
to 'Aux to All' (menu item 4A) to actually transmit this stereo signal.
The 'Stereo to Mono' and ‘Mono+ Emergency’ options can be selected when the transmitter is used in combination with an
interpretation system. The Aux. input(s) will be distributed to the Symmetrical Audio Input and Interpreters Module. In this
configuration the 'floor' signal should be connected to the Aux. inputs.
Menu Items
Option
Description
4H Aux. Input
Type:
*
-
Stereo
The Aux. inputs will be distributed in stereo to
all
channels when the
transmission mode (menu item 1) is set to ‘Aux to All’.
-
Stereo to Mono
The Aux-L and Aux-R inputs are combined into a mono signal and
distributed to the Symmetrical Audio Input and Interpreters Module
(when present).
-
Mono + Emergency
The Aux-L input is distributed to the Symmetrical Audio Input and
Interpreters Module (when present). The Aux-R input is distributed as
emergency signal to
all
channels when the emergency switch is closed.
2.5.14 Set sensitivity of the inputs
The sensitivity of the audio and Aux. inputs can be set in the Input Sensitivity menus (4I, 4J, 4K) . The sensitivity can be set the
same for all audio inputs (menu item 4K) or for each audio input separately.
Menu Items
Options
Value
Description
4I Sens.Aux.L
Level:
+6 ... +18 dBV
Set the required sensitivity for the left auxiliary input.
4J Sens.Aux.R
Level:
+6 ... +18 dBV
Set the required sensitivity for the right auxiliary input.
4K Sens.Inputs
Mode: Level:
-
All
-6 ... +6 dBV
Set the sensitivity of all audio inputs to a user defined level.
-
Per Input ...
Select this option to go to the 'Per Input Sensitivity Settings'
menu.
Per Input Sensitivity settings:
Menu Items
Options
Value
Description
4K Sens.Input nn Input
nr.: Level:
00...31
-6...+6 dBV
Select which input to set and select the required sensitivity.
The sensitivity screens also display a level meter for a visual indication of the actual signal strength:
▄
= low level,
█
= high
level,
▲
= overflow.
2.5.15 Choose transmitter name
The transmitter can be assigned a user-defined name. This name is used in the Transmitter Status screen. The name can be
edited in the Unit Name menu (4L).
Menu Items
Options
Description
4L Unit Name
Name:
-
Free text
Assign a user defined name to the transmitter (max. 16 characters).
The default name is 'Transmitter'.