2.5 Configuration
and
operation
The next sections give descriptions of the possible configuration options. Each description is followed by the relevant menu
items with detailed information per menu option.
The default values (see section ‘Reset all options to factory defaults’) are indicated by an asterix (*) when applicable.
2.5.1 Start-up
When the transmitter is switched on, the display shows the Transmitter Status screen, which is the first item of the Main menu.
The display also goes to this screen after 5 minutes of inactivity.
2.5.2 Main
menu
The main menu contains the screens to view the transmitter status and the radiator fault status. It also contains the entry points
to the Monitoring, Enquiry and Setup sub-menus.
Menu Item
Description
Transmitter Status
Shows the transmitter status (see section 2.5.3)
1 Fault Status
Shows the radiator fault status (see section 2.5.4)
2 Monitoring ...
Go to the 'Monitoring' sub-menu (see section 2.5.5)
3 Enquiry ...
Go to the 'Enquiry' sub-menu (see section 2.5.6)
4 Setup …
Go to the 'Setup' sub-menu (see sections 2.5.7 and higher)
2.5.3 View
transmitter
status
The first screen of the Main menu gives information about the present status of the transmitter. The screens shows the name of
the transmitter (1st line) and the present transmission mode (2nd line). See examples below. See section 2.5.7 to change the
transmission mode.
Transmitter
10 Channels DCN
Transmitter
Aux to All
Transmiter
Standby
Transmitter is transmitting 10 channels
from DCN.
Transmitter is transmitting the Aux inputs
on all channels.
Transmitter is in Standby mode (not
transmitting)
Menu Items
Options (read only)
Description
Transmitter Status
Name
The first line shows the user defined name of the transmitter (see
section 2.5.15).
Mode:
The second line shows the actual transmission mode:
-
nn Channels
Audio signals are distributed on nn channels.
-
Aux to All
The signal on the Aux. inputs is distributed on all channels.
-
nn Ch. Test
The test signals are distributed on nn channels.
-
Slave
The transmitter operates in slave-mode: the radiator signal on the
slave input is looped-through to all radiator outputs.
-
Standby
The transmitter is in stand by mode.
-
Emergency Call
An emergency signal from the Aux. inputs is distributed to all
channels.
DCN
The text 'DCN' is shown at the right side of the second line when a
DCN system is connected to the transmitter.