20.3 Appliance information
Enter the factory settings for the gas type and gas
pressure in the table below and then add the applic-
able gas type and gas pressure settings for once con-
version has been carried out.
E no.
FD
After-sales service tele-
phone number
Type of gas/gas pressure
The data can be found on
the rating plate.
Type of gas/gas pressure
Data following gas con-
version
20.4 Selecting the gas connection side
On many appliances, you can carry out the gas con-
nection on the right- or left-hand side. If necessary, you
can change the connection side.
Requirements
¡
Shut off the main gas line.
¡
Seal the gas connecting piece on the side that is not
being used with a blind plug.
1.
Place the new seal in the blind plug. Ensure that the
seal is seated correctly.
2. Note:
Use a torque wrench when connecting the ap-
pliance.
Secure the gas connecting piece to the appliance
using a 22 mm spanner
and place the blind plug
onto the connecting piece using a 24 mm spanner.
20-25
Nm
SW
22
SW
24
3.
After changing the connection side, carry out a leak
test. You can find additional information about this in
the section entitled "Leak and function test"
→
20.5 Installation
Only an officially authorised technician should connect
the appliance.
Preparing to install
This installation must conform with following:
¡
Local Gas Fitting Regulations
¡
Municipal Building Codes
¡
AGA Installation Code for Gas Burning Appliances
(AS 5601/AG 601).
¡
S.A.A. Wiring Code
¡
Local Electrical Regulations
¡
Any other statutory regulations
Before connecting
Before connecting the unit, check whether the local
connection conditions (type of gas) are cmpatible with
the unit’s setting. Observe any special conditions im-
posed by local suppliers (utilities). The specifications of
this appliance are stated on the data label located on
the rear of the cooker.
Clearances
A range hood fitted above the top must be installed ac-
cording to the installation instructions for the range
hood. A minimum distance of 650 mm is required for a
range hood and 750 mm for an exhaust fan.
Clearances to combustible materials
“Any adjonining wall surface (side or rear) situated
within 200 mm of any hob burner must be a suitable
non-combustible material from the edge for a height of
150 mm for the entire length of the cooker. Any com-
bustible construction above the maintop.”
Ensure that a power and gas supply are nearby. The
cooker should be located carefully so that the heat pro-
duced by it has plenty of space to escape.
Connection
Do not install the appliance behind a decorative door
or the door of a kitchen unit, as this may cause the ap-
pliance to overheat.
Electrical connection
An electrical 16 amp socket needs to be within 1,20 m
of the cooker to allow electrical connection. The socket
must remain accessibble after installation of the appli-
ance.
Note: Important
This appliance is connected to the mains (230 VAC) by
means of the connecting lead which must be fixed to
the kitchen unit to prevent it from coming into contact
with hot parts of the cooker. When making this connec-
tion make sure that the lead connot come into contact
with hot parts of the cooker.
Important:
This appliance must be earthed.
Gas connection
During the planning stage, consider the position of sup-
ply connections.
The cooker must be connected to the gas supply with
upstream connection of an isolation valve in accord-
ance with the respectively valid regulations. We recom-
mend that the isolation valve be fitted prior to the
cooker to enable isolation of cooker from gas supply.
The valve must be easily accessible at all times.
To find out the factory set gas type, see rear of cooker
next to gas connection.
Remove plastic cap from gas supply line prior to in-
stallation.