40/44
Technical data
Bosch Rexroth AG
, Type HAD...-1X/ and HAD...-2X/, RE 50150-B/10.20
Table 7: Fault table
Fault
Possible cause
Remedy
Oil loss at interfaces to
the outside
Incorrect order of assembly in service case
▶
Have the service performed by an expert only.
O-ring of the sealing is damaged and/or
hardened due to excessive oil temperature
▶
Have the gas valve replaced by an expert.
▶
Check the oil temperature.
Oil port cracked due to non-tension-free
assembly of the diaphragm type
accumulator
▶
Assemble it de-energized.
Inadmissible environmental force effect
▶
Assemble free of stress.
Damage to the oil valve during transport
▶
Perform a visual inspection after transport.
Impossible to assemble
Wrong thread
▶
Replace the affected parts.
Thread damaged
▶
Replace the affected parts.
15 Technical data
For the admissible technical data of the diaphragm type accumulator, refer to
data sheet 50150, see chapter 1.2 "Required and amending documentation".
The data sheet can be found on the Internet at
www.boschrexroth.com/various/utilities/mediadirectory
For further information, refer to the online product catalog
Industrial hydraulics:
www.boschrexroth.com/ics