6 720 819 528 (2016/02)
Therm 4000 S
22 | Problems
Note: breakdowns diagnosed by the water heater through the
signal lamp in the reset button combined with an indication in
the LCD panel result in the blocking of the appliance for safety
reasons. Once the problem is solved, you have to press the
reset button to start the appliance working again.
10
Environment / disposal
Environmental protection is a fundamental corporate strategy
of the Bosch Group.
The quality of our products, their efficiency and environmental
safety are all of equal importance to us and all environmental
protection legislation and regulations are strictly observed.
We use the best possible technology and materials for
protecting the environment taking into account of economic
considerations.
Packaging
We participate in the recycling programmes of the countries in
which our products are sold to ensure optimum recycling.
All of our packaging materials are environmentally friendly and
can be recycled.
Used appliances
Used appliances contain valuable materials that should be
recycled.
The various assemblies can be easily dismantled and synthetic
materials are marked accordingly. Assemblies can therefore be
sorted by composition and passed on for recycling or disposal.
F9
Safety Solenoid valve disconnected.
▶ Check connections.
1)
▶ Press the reset button.
FA
Fault in the gas shut-off valve.
▶ Call a qualified contractor.
FC
Buttons pressed for more than 30s.
▶ Release the button.
With indication,
but without existence
of solar thermal
system.
The ho water temperature selected is lower than the
minimum power that the appliance supplies.
▶ Increase the hot water flow.
If the problem persists, increase the setpoint
temperature.
With indication
and water
temperature low.
Echo
Appliance is making an abnormal noise (vibration).
▶ Call a qualified contractor.
1) only to be carried out by qualified contractors.
Display
Description
Solution
Table 11
Summary of Contents for GWH15
Page 24: ...6720819528 ...