en
36
Fault
Possible cause
Remedial action
Warning signal sounds,
Alarm display lights up.
The freezer compartment
is too warm! Frozen food
is at risk!
To switch off the warning signal, press
the Alarm button. Fig.
"
/5
Appliance is open.
Close the appliance.
Ventilation openings have
been covered.
Ensure that there is adequate ventilation.
Too much food was placed
in the freezer compartment
at once.
Do not exceed max. freezing capacity.
When the fault has been eliminated, the Alarm
display goes out shortly afterwards.
Freezer compartment door
was open for a long time;
temperature is no longer
reached.
The evaporator (refrigeration
generator) in the NoFrost
system is covered in thick ice
and can no
longer be defrosted fully
automatically.
To defrost the evaporator, remove the frozen
food with the compartments, insulate well
and store in a cool location.
Switch off the appliance and move it away
from the wall. Leave the appliance door open.
After approx. 20 min. the condensation begins
to run into the evaporation pan,
at the rear of the appliance. Fig.
+
To prevent the evaporation pan
from overflowing in this case,
mop up the condensation with a sponge.
The evaporator is defrosted when the water
stops running into the evaporation pan. Clean
the interior. Switch the appliance
back on again.