Always replace all the batteries/rechargeable batteries at the same time. Only use
batteries/rechargeable batteries from the same manufacturer and which have the
same capacity.
When inserting the batteries, ensure that the polarity is correct according to the il-
lustration on the inside of the battery compartment.
When the empty battery symbol first appears on the display, only a limited number of
measurements are still possible.
When the battery symbol is empty and flashes red, no further measurements are possible.
Replace the batteries or rechargeable batteries.
u
Take the batteries out of the measuring tool when you are not using it for a pro-
longed period of time
. The batteries can corrode and self-discharge during prolonged
storage.
Operation
Start-Up
u
Never leave the measuring tool unattended when switched on, and ensure the
measuring tool is switched off after use.
Others may be dazzled by the laser beam.
u
Protect the measuring tool from moisture and direct sunlight.
u
Do not expose the measuring tool to any extreme temperatures or variations in
temperature.
For example, do not leave it in a car for extended periods of time. In case
of large variations in temperature, allow the measuring tool to adjust to the ambient
temperature before putting it into operation. The precision of the measuring tool may
be compromised if exposed to extreme temperatures or variations in temperature.
u
Avoid substantial knocks to the measuring tool and avoid dropping it.
After strong
external influences on the measuring tool, you should always carry out an accuracy
check (see "Accuracy Check", page 36) before further work.
Switching On and Off
Press the
button to switch the measuring tool and the laser on.
You can also switch on the measuring tool without the laser by pressing the
button.
Press and hold the
button to switch off the measuring tool.
The measured values and device settings in the memory are retained.
Bosch Power Tools