Safety Notes
All instructions must be read and observed
in order to work safely with the measuring
tool. Never make warning signs on the
measuring tool unrecognisable. SAVE
THESE INSTRUCTIONS FOR FUTURE REFER-
ENCE AND INCLUDE THEM WITH THE MEASURING TOOL
WHEN GIVING IT TO A THIRD PARTY.
Caution – The use of other operating or adjusting
equipment or the application of other processing meth-
ods than those mentioned here can lead to dangerous
radiation exposure.
The measuring tool is provided with a warning label
(marked with number 5 in the representation of the
measuring tool on the graphics page).
If the text of the warning label is not in your national lan-
guage, stick the provided warning label in your national
language over it before operating for the first time.
Do not direct the laser beam at persons or
animals and do not stare into the direct or
reflected laser beam yourself, not even
from a distance.
You could blind somebody,
cause accidents or damage your eyes.
If laser radiation strikes your eye, you must deliberate-
ly close your eyes and immediately turn your head
away from the beam.
Do not make any modifications to the laser equipment.
Do not use the laser viewing glasses as safety goggles.
The laser viewing glasses are used for improved visualisa-
tion of the laser beam, but they do not protect against laser
radiation.
Do not use the laser viewing glasses as sun glasses or in
traffic.
The laser viewing glasses do not afford complete
UV protection and reduce colour perception.
Have the measuring tool repaired only through quali-
fied specialists using original spare parts.
This ensures
that the safety of the measuring tool is maintained.
Do not allow children to use the laser measuring tool
without supervision.
They could unintentionally blind
other persons or themselves.
Do not operate the measuring tool in explosive environ-
ments, such as in the presence of flammable liquids,
gases or dusts.
Sparks can be created in the measuring
tool which may ignite the dust or fumes.
Keep the measuring tool away from cardiac
pacemakers.
The magnet inside the measur-
ing tool generates a field that can impair the
function of cardiac pacemakers.
Keep the measuring tool away from magnetic data me-
dia and magnetically-sensitive equipment.
The effect of
the magnet can lead to irreversible data loss.
Product Description and
Specifications
Intended Use
The measuring tool is intended for levelling jobs with the use
of horizontal lines, vertical lines and the plumb point.
Product Features
The numbering of the product features shown refers to the
illustration of the measuring tool on the graphic page.
1
Exit opening for laser beam
2
Latch of battery lid
3
Battery lid
4
Serial number
5
Laser warning label
6
Locking grooves of measuring tool
7
On/Off switch
8
Vial of rotating platform
9
Tripod mount 5/8"
10
Height adjustment screw of rotating platform
11
Fine adjustment knob of rotating platform
12
Rotating platform
13
Locking grooves of rotating platform
14
Working without automatic levelling indicator
15
Power indicator/Battery warning
16
Vertical mode button
17
Horizontal mode button
18
Measuring plate with stand*
19
Tripod*
20
Protective pouch
21
Laser viewing glasses*
* The accessories illustrated or described are not included as
standard delivery.
Technical Data
Line laser
GLL 3-15
Article number
3 601 K63 E..
Working range
1)
– Laser lines
– Plumb point
m
m
15
5
Levelling accuracy of
laser lines
mm/m
±0.2
Self-levelling range, typically
°
±3
Levelling duration, typically
s
<4
1) The working range can be decreased by unfavourable environmental
conditions (e.g. direct sun irradiation).
2) only available in combination with the rotating platform
* dust and splash proof
The measuring tool can be clearly identified with the serial number
4
on
the type plate.
OBJ_BUCH-2194-001.book Page 6 Monday, May 19, 2014 12:24 PM