FLEXIDOME IP starlight 8000i
Preparing for installation | en
15
Bosch Security Systems B.V.
Installation manual
2021-02 | V02 | F.01U.385.211
When PoE power returns, the camera seamlessly switches back to PoE as its default power
source.
4.3.2
24V AC / 12-26V DC power input
Connect a SELV-LPS or a SELV Class 2 power supply with a rated supply voltage of 24V AC or
12-26V DC.
i
Notice!
When using a 24V AC power supply, do not make a ground connection with one of the 24V AC
supply leads. This will damage the camera.
4.3.3
10-pin I/O connector
Pin
Connection
1
+12V DC out
2
GND
3
ALARM OUT
4
ALARM OUT
5
GND
6
ALARM IN 1
7
ALARM IN 2
8
GND
9
AUDIO IN
10
AUDIO OUT
12V DC power output
The 12V DC output can be enabled/disabled via the web interface, and controlled via the
Alarm Task Editor.
Maximum load of 50 mA.
Alarm I/O
1.
Input:
Use the alarm input to connect external alarm devices such as door contacts or sensors:
–
TTL logic, +5V nominal, +40V DC maximum, DC coupled with 50k Ohm pull-up to
+3.3V.
–
Configurable as active low or active high.
Use a zero potential make-contact or switch as the actuator (with a bounce-free contact
system).
2.
Output:
Use the alarm output for switching external devices such as lamps or sirens. The alarm
output switching capability has a maximum voltage of 30V AC or +40V DC; maximum 0.5 A
continuous, 10 VA.