UHI-ASBG-0 Series
Installing the Housing | en
23
Bosch Security Systems, Inc.
Installation Manual
September 15, 2006 | F01U032279_01
13
Installing the Housing
This chapter outlines the procedures needed to install the UHI-ASBG-0 Indoor Housing Series.
Installation should be made by a qualified service person and all local codes should be con-
formed to.
13.1
Opening the Cover
The UHI-ASBG-0 housing is secured with two (2) tamper-resistant screws. To open the cover,
use the supplied tamper-resistant wrench (948002-00-00 M3.5 T20) to remove the screws.
Fig. 13.1
Opening the Cover
13.2
Feed-through Wiring
The UHI-ASBG-0 features feed-through wiring holes which are used to feed the cabling
through. Prior to mounting the camera, remove the rear (2) or bottom (2) rubber dome plugs
and install the NPT fittings (see
Section 13.3: NPT Fittings
).
13.3
NPT Fittings
The NPT fittings ensure a tight seal. Depending on how the UHI-ASBG-0 is mounted, the NPT
fittings can be installed either in the rear or from the bottom of the housing. The supplied 3/8
in. NPT fittings accept a round cable with diameters from 4.3 mm (0.17 in.) to 11.4 mm
(0.45 in.). The two larger 1/2 in. NPT fittings accept cables with diameters from 6.5 mm
(0.26 in.) to 10.5 mm (0.42 in.).
Fig. 13.2
Installing the NPT Fittings
Fig. 13.3
NPT Exploded View
Sealing Nut
Rubber Washer
Screw Nut (discard if using 3/8 in. NPT for bottom openings)
NPT Fitting