EX65 Explosion-protected Camera
Connections | en
17
Bosch Security Systems, Inc.
Instruction Manual
F.01U.412.061 | 2.0 | 2011.08
5
Connections
All required connections are accessible by removing the end cap conveniently located in the
rear of the EX65.
5.1
Power Cable Requirements
Connect power from a 12 - 24 VAC or 12 - 24 VDC class 2 power supply. Use AWG 16 to 22
stranded wire or AWG 16 to 26 solid wire; cut back 5 mm (0.2 in.) of insulation.
5.1.1
Wire Distance Guide
This table lists the maximum wire distances for 14, 16, and 18 AWG wires connected to a
24 VAC camera.
5.2
Coax Cable Requirements
NOTICE!
Take care not to drop the end caps to prevent damage to the cap threads.
WARNING!
Before proceeding, disconnect the power from the power supply cable. Ensure that the
voltage of the unit matches the voltage and type of the power supply being used.
Cable size
Stranded wire: AWG 16 to 22
Solid wire: AWG 16 to 26
Cable shape
Round
Conductors
2-conductor version
Environmental
Outdoor rated
Watts
14 AWG (2.5 mm)
16 AWG (1.5 mm)
18 AWG (1.0 mm)
All Models
20
289 m
(949 ft)
182 m
(597 ft)
114 m
(376 ft)
Cable type
RG-59/U for runs < 300 m (1000 ft)
RG-11/U for runs < 600 m (2000 ft)
Cable size
Outside diameter between 4.6 mm to 7.9 mm (0.181 in. to 0.312 in.)
Cable shape
Round
Shield
> 93% braided copper shield
Center conductor
Stranded copper center
DC resistance
< 15 Ohm/1000 m (RG-59/U)
< 6 Ohm/1000 m (RG-11/U)
Cable impedance
75 Ohm
Agency rating
UL
Environmental
Outdoor rated
Temperature rating > 80 degrees C
Sources
Belden 9259