8.5.3
Synchronization submenu
8.5.4
Alarm I/O submenu
8.5.5
Connections submenu
Item
Selection
Description
Synchronization
Internal
Line lock
HV lock,
Genlock,
Internal - for free running camera operation.
Line lock - to lock to the AC power supply
HV lock - locks the camera to the sync signal supplied to
the SYNC connector.
Genlock - locks the camera’s subcarrier to the signal
supplied to the SYNC connector.
Horizontal phase
-25 . . 0 . . +25 Adjusts the horizontal phase offset.
Subphase
0, 2 . . . 358
Adjusts the subcarrier phase.
EXIT
Returns to Install menu.
Item
Selection
Description
Alarm input
None, high,
low
Select none to disable the alarm input. Select active-high
or active-low for the alarm input connector.
Alarm action
None,
Mode 1 to 6,
Mono
Selects the operating mode of the camera when the alarm
input is active.
Alarm output
VMD,
External
device,
Night mode
active,
Filter toggle
VMD: - output relay closes on VMD alarms.
External device: - make the output relay available to
remote communication devices.
Night mode active: - output relay closes when camera is in
monochrome mode.
Filter toggle: - output relay closes just before the IR filter
starts moving and opens when video level has stabilized
(2 to 3 seconds)
EXIT
Returns to Install menu.
Item
Selection
Description
Sync. input
High Z,
75 ohm
Select 75 ohm if the external sync input is not
terminated elsewhere.
Notch filter
On, Off
Switches notch filter on or off. The notch filter can
remove a Moiré pattern or color artifacts caused by
closely spaced vertical lines or objects (e.g. vertical
security bars over windows).