background image

8

en

Cleaning and care

Isolate the extractor hood by pulling out the 

mains plug or switching off the fuse.

 

When cleaning the grease filters, remove 

grease deposits from accessible parts of the 

housing. This prevents the risk of fire and en

-

sures that the extractor hood continues operat-

ing at maximum efficiency.

 

Clean the extractor hood with a hot soap solu-

tion or a mild window cleaner.

 

Do not scrape off dried-on dirt but wipe off with 

a damp cloth.

 

Do not use scouring agents or abrasive spong-

es.

 

Note: 

Do not use alcohol (spirit) on plastic sur-

faces, as dull marks may appear.

 

Caution: 

Ensure that the kitchen is adequately 

ventilated. Avoid naked flames!

 

Clean the operating buttons with a mild soapy 

solution and a soft, damp cloth only. Do not use 

stainless-steel cleaner to clean the operating but-

tons.

Stainless steel surfaces:

 

Use a mild non-abrasive stainless steel cleaner.

 

Clean the surface in the same direction as it 

has been ground and polished.

 

Do not use any of the following to clean stain-

less steel surfaces: abrasive sponges, cleaning 

agents containing sand, soda, acid or chloride!

Aluminium and plastic surfaces:

 

Use a soft, non-linting window cloth or micro-

fibre cloth.

 

Do not use dry cloths.

 

Use a mild window cleaning agent.

 

Do not use aggressive, acidic or caustic clean-

ers.

 

Do not use abrasive agents.

Replacing the light bulbs

1. 

Switch off the extractor hood and pull out the 

mains plug or switch off the electricity supply at 

the fuse box.

 

When switched on, the halogen bulbs become 

very hot. Even for some time after the bulbs have 

been switched off there is still a risk of burns.

2. 

With the aid of a screwdriver pull out the bulbs 

or, if it is not easy, r

emove the 2 screws fixing 

the Lighting support, and pull it out of from the 

Hood.

3. 

Replace the halogen light bulb (conventional 

halogen bulb, 12 Volt, max. 20 Watt, GU4 bulb-

holder).

 

Caution: 

Plug-in bulbholder.

4. 

Replace the Support, fixing it in place with the 

two screws removed as above.

5. 

Restore the power by inserting the mains plug 

or switching on the fuse.

Note: 

If the light does not function, check that the 

bulbs have been inserted correctly.

If you encounter a problem

If you have any questions or if a fault occurs, please 

call Customer Service.
(See list of Customer Service representatives).
When you call, please quote the following:

E-Nr. 

FD

Enter the relevant numbers into the box above. The 

E-Nr. (product no.) and FD (production date) are 

shown on the nameplate which can be seen inside 

the extractor hood after the filter frame has been 

detached.

 

The manufacturer of the extractor hoods 

accepts no liability for complaints which can 

be attributed to the design and layout of the 

pipework.

Summary of Contents for DWK096751B

Page 1: ...Internet http www bosch hausgeraete de Bosch Info Team de Tel 01 80 5 30 40 50 E 0 14 Min DTAG DWK096751B en Operating and installation instructions ...

Page 2: ......

Page 3: ...n conveyed back into the kitchen The grease filter absorbs the grease particles in the kitchen vapours The activated carbon filter binds the odorous substances If no activated carbon filter is installed it is not possible to bind the odorous substances in the cooking vapours Lighting Light fan switches Ducting panels Chimney Operating modes Exhaust air mode The extractor hood fan extracts the kitc...

Page 4: ...ood is situated over a gas hob operate the hood at maximum setting if three or more gas hotplates are operated simultaneously Safety instructions Do not flambé food directly under the extractor hood Risk of grease filter catching fire due to flames The hotplates must always be covered with a utensil Restrictions apply to the use of the extractor hood over a solid fuel burner coal wood etc See Inst...

Page 5: ...t shows H E By pressing this key it is possible to set the delayed shutdown of the appliance to 30 minutes This function is suitable for a complete elimination of the residual smells It can be activated at any position and it is deactivated by pressing the key again or by switching off the motor The point low to right flashes F With a short press turns light on and off With an ex tended press turn...

Page 6: ...ducting panels Remove the filters one by one Ducting panels The ducting panels must never be washed in a dishwasher Open the ducting panels pulling them down wards Disconnect the panels from the hood canopy by sliding the fixing pin lever Any kind of bending of the filters has to be avoided when washing them Before fitting them again into the hood make sure that they are completely dry The colour ...

Page 7: ...connection press and hold B key When releasing the key two rotating rectangles appear on the display Within 3 seconds press the B key until a flash ing confirmation appears on the dispaly 2 flashes with C sign charcoal filter satu ration alarm ACTIVATED 1 flash with C sign charcoal filter satura tion alarm DEACTIVATED Replacing the activated carbon filter Reset of the alarm signal Switch off the h...

Page 8: ...aning agent Do not use aggressive acidic or caustic clean ers Do not use abrasive agents Replacing the light bulbs 1 Switch off the extractor hood and pull out the mains plug or switch off the electricity supply at the fuse box When switched on the halogen bulbs become very hot Even for some time after the bulbs have been switched off there is still a risk of burns 2 With the aid of a screwdriver ...

Page 9: ...pliance render it unusable You received your new appliance in a protective shipping carton All packaging materials are environ mentally friendly and recyclable Please contribute to a better environment by disposing of packaging materials in an environmentally friendly manner Please ask your dealer or inquire at your local au thority about current means of disposal The extractor hood can be used in...

Page 10: ...an be achieved if combustion air can flow through non lockable openings e g in doors win dows and via the airintake exhaust air wall box or by other technical measures such as reciprocal interlocking etc If the air intake is inadequate there is a risk of poisoning from combustion gases which are drawn back into the room An air intake exhaust air wall box by itself is no guarantee that the limiting...

Page 11: ...erminal in the plug marked E or with the symbol or coloured green or green and yel low 2 Connect the blue Neutral wire to the terminal in the plug marked N or coloured black 3 Connect the brown Live wire to the terminal marked L or coloured red The extractor hood should only be connected to an earthed socket that has been installed according to relevant regulations If possible site the earthed soc...

Page 12: ...imum distance between the hob and the extractor hood is maintained 400 mm for the electric or gas hob 4 Drill ø 8 mm holes A and B for the extractor hood Drill ø 8 mm holes C for the chimney brackets 5 Insert plugs 11 into the holes so that they are flush with the wall 6 Fix the brackets 7 2 1 using the 12a screws supplied In case of hood installation in recycling ver sion with the chimney the upp...

Page 13: ...ert the connection extension pieces laterally 14 1 in connection 15 Make sure that the outlet of the extension pieces 14 1 is horizontally and vertically aligned with the chimney outlets Connect the air outlet connection 15 to the hood body outlet using either a pipe ø 150 mm Chimney assembly Upper Chimney Slightly widen the two sides of the upper Chim ney and hook them behind the brackets 7 2 1 m...

Page 14: ...Notizen Notes Note Notulen Notas σημείωση ...

Page 15: ...DHZ5475 ...

Page 16: ...Robert Bosch Hausgeräte GmbH 436004612_01 090218 ...

Reviews: