background image

4

en

Before using for the first time

Important notes:

 

The Instructions for Use apply to several ver-

sions of this appliance. Accordingly, you may 

find descriptions of individual features that do 

not apply to your specific appliance.

 

This extractor hood complies with all  relevant 

safety regulations.

 

Repairs 

should be carried out by qualified tech

-

nicians only.

 

Improper repairs may put the user at con

-

siderable risk.

 

Before using your appliance for the first time, 

please read these Instructions for Use carefully. 

They contain important information concerning 

your personal safety as well as on use and care 

of the appliance.

 

Please retain the operating and installation 

instructions for a subsequent owner.

 

This appliance is labelled in 

accordance with European 

Directive 2002/96/EG con-

cerning used electrical and 

electronic appliances (waste 

electrical and electronic equip-

ment – WEEE). The guideline 

determines the framework for the return and 

recycling of used appliances as applicable 

throughout the EU.

Gas hobs / gas cookers

 

Do not use all the gas hotplates simultane-

ously for a prolonged period (max. 15 minutes) at 

maximum thermal load, otherwise there is a risk of 

burns if the housing surfaces are touched or a risk 

of damage to the extractor hood. If the extractor 

hood is situated over a gas hob, operate the hood at 

maximum setting if three or more gas hotplates are 

operated simultaneously.

!

Safety instructions

 

Do not flambé food directly under the extractor 

hood.

 

Risk of grease filter catching fire due to flames.

 

The hotplates must always be covered with a 

utensil.

 

Restrictions apply to the use of the extractor 

hood over a solid-fuel burner (coal, wood, etc.). 

(See Installation instructions).

 

Do not use the appliance if damaged.

 

The appliance is not intended for use by young 

children or infirmed persons without supervision.

Young children should be supervised to ensure they 

do not play with the appliance.

 

If the connecting cable for this appliance 

is damaged, the cable must be replaced by the 

manufacturer or his customer service or a similarly 

qualified person in order to prevent serious injury to 

the user.

 

The appliance may be connected to the mains 

by a qualified technician only.

 

Dispose of packaging materials properly (see 

Installation instructions).

 

This extractor hood is designed for domestic 

use only.

 

Light bulbs must always be fitted when the ex

-

tractor hood is in use.

 

Defective bulbs should be replaced immediately 

to prevent the remaining bulbs from overloading.

 

Never operate the extractor hood without a 

grease filter.

 

Overheated fat or oil can easily catch fire.

If you are cooking with fat or oil, e.g. chips, etc., 

never leave the cooker unattended.

 Carefully clean the extractor hood before switch-

ing on for the first time.

Summary of Contents for DWK096751B

Page 1: ...Internet http www bosch hausgeraete de Bosch Info Team de Tel 01 80 5 30 40 50 E 0 14 Min DTAG DWK096751B en Operating and installation instructions ...

Page 2: ......

Page 3: ...n conveyed back into the kitchen The grease filter absorbs the grease particles in the kitchen vapours The activated carbon filter binds the odorous substances If no activated carbon filter is installed it is not possible to bind the odorous substances in the cooking vapours Lighting Light fan switches Ducting panels Chimney Operating modes Exhaust air mode The extractor hood fan extracts the kitc...

Page 4: ...ood is situated over a gas hob operate the hood at maximum setting if three or more gas hotplates are operated simultaneously Safety instructions Do not flambé food directly under the extractor hood Risk of grease filter catching fire due to flames The hotplates must always be covered with a utensil Restrictions apply to the use of the extractor hood over a solid fuel burner coal wood etc See Inst...

Page 5: ...t shows H E By pressing this key it is possible to set the delayed shutdown of the appliance to 30 minutes This function is suitable for a complete elimination of the residual smells It can be activated at any position and it is deactivated by pressing the key again or by switching off the motor The point low to right flashes F With a short press turns light on and off With an ex tended press turn...

Page 6: ...ducting panels Remove the filters one by one Ducting panels The ducting panels must never be washed in a dishwasher Open the ducting panels pulling them down wards Disconnect the panels from the hood canopy by sliding the fixing pin lever Any kind of bending of the filters has to be avoided when washing them Before fitting them again into the hood make sure that they are completely dry The colour ...

Page 7: ...connection press and hold B key When releasing the key two rotating rectangles appear on the display Within 3 seconds press the B key until a flash ing confirmation appears on the dispaly 2 flashes with C sign charcoal filter satu ration alarm ACTIVATED 1 flash with C sign charcoal filter satura tion alarm DEACTIVATED Replacing the activated carbon filter Reset of the alarm signal Switch off the h...

Page 8: ...aning agent Do not use aggressive acidic or caustic clean ers Do not use abrasive agents Replacing the light bulbs 1 Switch off the extractor hood and pull out the mains plug or switch off the electricity supply at the fuse box When switched on the halogen bulbs become very hot Even for some time after the bulbs have been switched off there is still a risk of burns 2 With the aid of a screwdriver ...

Page 9: ...pliance render it unusable You received your new appliance in a protective shipping carton All packaging materials are environ mentally friendly and recyclable Please contribute to a better environment by disposing of packaging materials in an environmentally friendly manner Please ask your dealer or inquire at your local au thority about current means of disposal The extractor hood can be used in...

Page 10: ...an be achieved if combustion air can flow through non lockable openings e g in doors win dows and via the airintake exhaust air wall box or by other technical measures such as reciprocal interlocking etc If the air intake is inadequate there is a risk of poisoning from combustion gases which are drawn back into the room An air intake exhaust air wall box by itself is no guarantee that the limiting...

Page 11: ...erminal in the plug marked E or with the symbol or coloured green or green and yel low 2 Connect the blue Neutral wire to the terminal in the plug marked N or coloured black 3 Connect the brown Live wire to the terminal marked L or coloured red The extractor hood should only be connected to an earthed socket that has been installed according to relevant regulations If possible site the earthed soc...

Page 12: ...imum distance between the hob and the extractor hood is maintained 400 mm for the electric or gas hob 4 Drill ø 8 mm holes A and B for the extractor hood Drill ø 8 mm holes C for the chimney brackets 5 Insert plugs 11 into the holes so that they are flush with the wall 6 Fix the brackets 7 2 1 using the 12a screws supplied In case of hood installation in recycling ver sion with the chimney the upp...

Page 13: ...ert the connection extension pieces laterally 14 1 in connection 15 Make sure that the outlet of the extension pieces 14 1 is horizontally and vertically aligned with the chimney outlets Connect the air outlet connection 15 to the hood body outlet using either a pipe ø 150 mm Chimney assembly Upper Chimney Slightly widen the two sides of the upper Chim ney and hook them behind the brackets 7 2 1 m...

Page 14: ...Notizen Notes Note Notulen Notas σημείωση ...

Page 15: ...DHZ5475 ...

Page 16: ...Robert Bosch Hausgeräte GmbH 436004612_01 090218 ...

Reviews: