background image

 

INSTALLATION, OPERATION  

& MAINTENANCE INSTRUCTIONS 

FOR EVERDURE RANGEHOOD 

 

 

Model: 

RIES912 

 

Summary of Contents for RIES912

Page 1: ...INSTALLATION OPERATION MAINTENANCE INSTRUCTIONS FOR EVERDURE RANGEHOOD Model RIES912 ...

Page 2: ...instructions carefully to avoid misuse and hazards It is important that you retain these instructions and your proof of purchase along with any other important documents about this product for future reference Due to continual product development Everdure reserves the right to alter specifications or appearances without notice CONTENTS IMPORTANT SAFETY INSTRUCTIONS 1 APPLIANCE DETAILS 2 INSTALLATI...

Page 3: ...r to cooking 13 It is recommended to leave the range hood in operation for 15 minutes after cooking is terminated in order to completely eliminate cooking vapours and odours 14 Turn off the range hood when not in use 15 Do not use the range hood if it is damaged especially the supply cord and the case 16 Do not immerse the range hood in liquid 17 The exhaust air must not be discharged into a flue ...

Page 4: ... 3 3 Insert the axial rod 4 into the holes 5 on the body of the rangehood 4 Repeat for both halves Installation of the Rangehood If you have an air outlet to the outside your rangehood can be connected as below by means of an extraction duct enamel aluminum flexible pipe or non flammable material with an interior diameter of 150mm 1 Before installation turn the unit off and unplug it from the outl...

Page 5: ...exploded screws to fix the hanging board to a concrete ceiling Use 8pcs of M4 10 big flat screws and M4 nut with gasket to connect the angle iron to the hanging board Use 16pcs M4 10 big flat screws and M4 nut with gasket to connect the angle iron and another angle iron the overlap length of angle iron can not be less than 100mm 5 Let one end of the expansion pipe go outside through the 170mm hole...

Page 6: ...e these basic instructions will reduce the performance and increase noise levels of the cooker hood Any installation work must be carried out by a qualified electrician or competent person Do not connect the ducting system of the hood to any existing ventilation system which is being used for any other appliance such as warmer tube gas tube hot wind tube The angle of the bend of the expansion pipe...

Page 7: ...e Department Motor failed Contact Service Department Light does not work motor does not work House fuses blown Reset Replace fuses Power cord loose or disconnected Refit cord to power outlet Switch power outlet on Oil leakage One way valve and the air ventilation entrance are not tightly sealed Take down the one way valve and seal with sealant Leakage from the connection of U shaped section and co...

Page 8: ...f metal It is recommended that this is undertaken every 4 6 weeks depending on frequency of use The filters can be cleaned with warm soapy water or a cloth Cleaning of the range hood must be performed as described above otherwise there is a possibility of a fire hazard due to grease and fat build up REPLACING THE LIGHTS 1 Before changing the lights make sure that the appliance is unplugged from th...

Page 9: ...ON A division of Shriro Australia Pty Ltd 104 Vanessa Street Kingsgrove NSW 2208 AUSTRALIA 1300 355 541 www everdure com NEW ZEALAND 09 415 6000 www everdure co nz IM Ref RIES912 v2 13 06 2019 FOR INDOOR USE ONLY ...

Reviews: