Warning

Risk of electric shock!

A defective appliance may cause electric 

shock. Never switch on a defective 

appliance. Unplug the appliance from the 

mains or switch off the circuit breaker in the 

fuse box. Contact the after-sales service.

Risk of electric shock!

Incorrect repairs are dangerous. Repairs 

may only be carried out and damaged 

power cables replaced by one of our 

trained after-sales technicians. If the 

appliance is defective, unplug the appliance 

from the mains or switch off the circuit 

breaker in the fuse box. Contact the after-

sales service.

Risk of electric shock!

Do not use any high-pressure cleaners or 

steam cleaners, which can result in an 

electric shock.

Causes of damage
Caution!

Risk of damage due to corrosion. Always 

switch on the appliance while cooking to avoid 

condensation. Condensate can produce 

corrosion damage.
Always replace faulty bulbs to prevent the 

remaining bulbs from overloading.
Risk of damage due to ingress of humidity into 

the electronic circuitry. Never clean operator 

controls with a wet cloth.
Surface damage due to incorrect cleaning. 

Clean stainless steel surfaces in the direction 

of the grain only. Do not use any stainless 

steel cleaners for operator controls.
Surface damage due to strong or abrasive 

cleaning agents. Never use strong and 

abrasive cleaning agents.
Risk of damage from returning condensate. 

Install the exhaust duct in such a way that it 

falls away from the appliance slightly (1° 

slope).

7

Environmental protection

Environmental protection

Environmentally-friendly disposal

Dispose of packaging in an environmentally-friendly 

manner.

Ç

Operating modes

Operating modes

Exhaust air mode

Note: 

The exhaust air must not be conveyed into a 

functioning smoke or exhaust gas flue or into a shaft 

which is used to ventilate installation rooms which 

contain heat-producing appliances.

Before conveying the exhaust air into a non-

functioning smoke or exhaust gas flue, obtain the 

consent of the heating engineer responsible.

If the exhaust air is conveyed through the outer wall, 

a telescopic wall box should be used.

Circulating-air mode

Notes

To bind odours in circulating-air mode, you must 

install an activated carbon filter. The different options 

for operating the appliance in circulating-air mode 

can be found in the brochure. Alternatively, ask your 

dealer. The required accessories are available from 

specialist retailers, from customer service or from 

the Online Shop.

For appliances with an additional internal filter, only 

the CleanAir recirculation module (see Accessories 

for circulating-air mode) can be used.

This appliance is labelled in accordance with 

European Directive 2012/19/EU concerning 

used electrical and electronic appliances 

(waste electrical and electronic equipment - 

WEEE). The guideline determines the 

framework for the return and recycling of used 

appliances as applicable throughout the EU.

The air which is drawn in is cleaned 

by the grease filters and conveyed to 

the exterior by a pipe system.

The air which is drawn in is cleaned by 

the grease filters and an activated 

carbon filter and conveyed back into the 

kitchen.

Summary of Contents for DWA097E51A

Page 1: ...en Instructions for installation and use Extractor hood ...

Page 2: ...ge which is caused by improper use or incorrect operation This appliance is intended for use up to a maximum height of 2000 metres above sea level This appliance may be used by children over the age of 8 years old and by persons with reduced physical sensory or mental capabilities or by persons with a lack of experience or knowledge if they are supervised or are instructed by a person responsible ...

Page 3: ...te the appliance without the grease filter Risk of fire Grease deposits in the grease filter may catch fire Never work with naked flames close to the appliance e g flambéing Do not install the appliance near a heat producing appliance for solid fuel e g wood or coal unless a closed non removable cover is available There must be no flying sparks Risk of fire Hot oil and fat can ignite very quickly ...

Page 4: ... slightly 1 slope 7Environmental protection EnvironmentalprotectionEnvironmentally friendly disposal Dispose of packaging in an environmentally friendly manner ÇOperating modes OperatingmodesExhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms which contain heat producing appliances Bef...

Page 5: ...nd hold the B button until the desired brightness is reached Saturation display When the metal mesh grease filters or the activated carbon filter are saturated a signal sounds for approx 4 seconds after the fan is switched off In addition the corresponding symbol appears in the display Metal mesh grease filter Activated carbon filter If you have not yet done so the metal mesh grease filters should...

Page 6: ...When the metal mesh grease filters or the activated carbon filter are saturated a signal sounds for approx 4 seconds after the fan is switched off In addition the corresponding symbol appears in the display Metal mesh grease filter Activated carbon filter If you have not yet done so the metal mesh grease filters should be cleaned or the activated carbon filter changed now For instructions on how t...

Page 7: ...too quickly or too slowly it can be changed accordingly 1 When the fan is switched off press the 1 button and hold it for approx 4 seconds The setting is displayed 2 Press the or button to change the setting of the sensor control 3 To confirm the entries press and hold the 1 button for approx 4 seconds Fan run on time The fan run on time is possible at every fan setting except boost and boost ƒ Se...

Page 8: ...ning agents Cleaning agents with a high alcohol content Hard scouring pads or cleaning sponges High pressure cleaners or steam cleaners Wash new sponge cloths thoroughly before use Follow all instructions and warnings included with the cleaning agents Cleaning the metal mesh grease filters These instructions apply to several appliance variants It is possible that individual features are described ...

Page 9: ...d under the metal mesh grease filter 2 Fold the metal mesh grease filter upwards locking it in place 3Trouble shooting TroubleshootingMalfunctions often have simple explanations Please read the following notes before calling the after sales service Warning Risk of electric shock Incorrect repairs are dangerous Repairs may only be carried out and damaged power cables replaced by one of our trained ...

Page 10: ...The rating plate with these numbers can be found inside the appliance remove the metal mesh grease filter to gain access You can make a note of the numbers of your appliance and the telephone number of the after sales service in the space below to save time should it be required Please be aware that a visit by an after sales engineer will be charged if a problem turns out to be the result of opera...

Page 11: ...d installation instructions for additional special accessories e g for circulating air mode The surfaces of the appliance are sensitive Avoid damaging them during installation 5 6 7 8 1 DHZ 5325 channel width 260 mm 2 DHZ 5326 channel width 260 mm 3 DHZ 5345 channel width 345 mm 4 DHZ 5346 channel width 345 mm 5 DSZ 6200 channel width 260 mm 6 DSZ 5201 channel width 260 mm 7 DSZ 6240 channel width...

Page 12: ...pendent heat producing appliance is being operated Room air dependent heat producing appliances e g gas oil wood or coal operated heaters continuous flow heaters or water heaters obtain combustion air from the room in which they are installed and discharge the exhaust gases into the open air through an exhaust gas system e g a chimney In combination with an activated vapour extractor hood room air...

Page 13: ...formation GeneralinformationExhaust air mode Warning Risk of death Risk of poisoning from flue gases that are drawn back in The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms that contain heating appliances If the exhaust air is to be conveyed into a non functioning smoke or exhaust gas flue you must obtai...

Page 14: ... 3 mm Only an electrician may install the fixed connection We recommend installing a residual current circuit breaker RCCB in the appliance s power supply circuit 5Installation InstallationPreparing the installation Caution Ensure that there are no electric wires gas or water pipes in the area where holes are to be made 1 Mark a vertical centre line on the wall from the ceiling to the lower edge o...

Page 15: ...connector and seal Exhaust air pipe Ø 120 mm 1 Attach the reducing connector directly to the air pipe connector 2 Attach the exhaust air pipe to the reducing connector 3 Seal both joints appropriately Attaching the flue duct Warning Risk of injury From sharp edges during installation Always wear protective gloves while installing the appliance 1 Separate the flue ducts To do this remove the adhesi...

Page 16: ...961015 9001017124 9001017124 Robert Bosch Hausgeräte GmbH Carl Wery Straße 34 81739 München Germany www bosch home com ...