background image

en

    Customer service

10

Note: 

When inserting halogen bulbs, do not touch the 

glass bulb. Use a clean cloth to insert the halogen 

bulbs.

1.

Carefully remove the bulb ring using a suitable tool.

2.

Remove the bulb and replace it with a bulb of the 

same type.

3.

Fit the bulb cover.

4.

Plug in the mains plug and switch the fuse back on.

Replacing filament bulbs

Important! 

Only use bulbs of the same type and 

wattage.

1.

Lift the bulb cover slightly and move it towards the 

outside of the appliance.

2.

Unscrew the bulb and replace it with a bulb of the 

same type.

3.

Fit the bulb cover.

4.

Plug in the mains plug and switch the fuse back on.

LED lights

Defective LED lights may be replaced by the 

manufacturer, their customer service or a qualified 

technician (electrician) only.

:

Warning

Risk of injury!

The light emitted by LED lights is very dazzling, and can 

damage the eyes (risk group 1). Do not look directly 

into the switched on LED lights for longer than 

100 seconds.

4

Customer service

Customer service

When calling us, please give the product number (E 

no.) and the production number (FD no.) so that we can 

provide you with the correct advice. The rating plate 

with these numbers can be found inside the appliance 

(remove the metal mesh grease filter to gain access).
You can make a note of the numbers of your appliance 

and the telephone number of the after-sales service in 

the space below to save time should it be required.

Please be aware that a visit by an after-sales engineer 

will be charged if a problem turns out to be the result of 

operator error, even during the warranty period.
Please find the contact data of all countries in the 

enclosed customer service list.

To book an engineer visit and product advice

Rely on the professionalism of the manufacturer. You 

can therefore be sure that the repair is carried out by 

trained service technicians who carry original spare 

parts for your appliances.

Accessories for circulating-air mode

(not included in the delivery)

Notes

Follow the installation instructions supplied with the 

accessories.

For appliances with an additional internal filter, only 

the CleanAir recirculation module can be used.

Basic equipment: Starter set for circulating-air mode - 

narrow

Throw-away filter

Basic equipment: Starter set for circulating-air mode - 

wide

Throw-away filter

E no.

FD no.

After-sales service

O

GB

0344 892 8979 

Calls charged at local or mobile rate.

IE

01450 2655 

0.03 € per minute at peak. Off peak 0.0088 € per 

minute.

1

2

3

4

Summary of Contents for DWA097E51A

Page 1: ...en Instructions for installation and use Extractor hood ...

Page 2: ...ge which is caused by improper use or incorrect operation This appliance is intended for use up to a maximum height of 2000 metres above sea level This appliance may be used by children over the age of 8 years old and by persons with reduced physical sensory or mental capabilities or by persons with a lack of experience or knowledge if they are supervised or are instructed by a person responsible ...

Page 3: ...te the appliance without the grease filter Risk of fire Grease deposits in the grease filter may catch fire Never work with naked flames close to the appliance e g flambéing Do not install the appliance near a heat producing appliance for solid fuel e g wood or coal unless a closed non removable cover is available There must be no flying sparks Risk of fire Hot oil and fat can ignite very quickly ...

Page 4: ... slightly 1 slope 7Environmental protection EnvironmentalprotectionEnvironmentally friendly disposal Dispose of packaging in an environmentally friendly manner ÇOperating modes OperatingmodesExhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms which contain heat producing appliances Bef...

Page 5: ...nd hold the B button until the desired brightness is reached Saturation display When the metal mesh grease filters or the activated carbon filter are saturated a signal sounds for approx 4 seconds after the fan is switched off In addition the corresponding symbol appears in the display Metal mesh grease filter Activated carbon filter If you have not yet done so the metal mesh grease filters should...

Page 6: ...When the metal mesh grease filters or the activated carbon filter are saturated a signal sounds for approx 4 seconds after the fan is switched off In addition the corresponding symbol appears in the display Metal mesh grease filter Activated carbon filter If you have not yet done so the metal mesh grease filters should be cleaned or the activated carbon filter changed now For instructions on how t...

Page 7: ...too quickly or too slowly it can be changed accordingly 1 When the fan is switched off press the 1 button and hold it for approx 4 seconds The setting is displayed 2 Press the or button to change the setting of the sensor control 3 To confirm the entries press and hold the 1 button for approx 4 seconds Fan run on time The fan run on time is possible at every fan setting except boost and boost ƒ Se...

Page 8: ...ning agents Cleaning agents with a high alcohol content Hard scouring pads or cleaning sponges High pressure cleaners or steam cleaners Wash new sponge cloths thoroughly before use Follow all instructions and warnings included with the cleaning agents Cleaning the metal mesh grease filters These instructions apply to several appliance variants It is possible that individual features are described ...

Page 9: ...d under the metal mesh grease filter 2 Fold the metal mesh grease filter upwards locking it in place 3Trouble shooting TroubleshootingMalfunctions often have simple explanations Please read the following notes before calling the after sales service Warning Risk of electric shock Incorrect repairs are dangerous Repairs may only be carried out and damaged power cables replaced by one of our trained ...

Page 10: ...The rating plate with these numbers can be found inside the appliance remove the metal mesh grease filter to gain access You can make a note of the numbers of your appliance and the telephone number of the after sales service in the space below to save time should it be required Please be aware that a visit by an after sales engineer will be charged if a problem turns out to be the result of opera...

Page 11: ...d installation instructions for additional special accessories e g for circulating air mode The surfaces of the appliance are sensitive Avoid damaging them during installation 5 6 7 8 1 DHZ 5325 channel width 260 mm 2 DHZ 5326 channel width 260 mm 3 DHZ 5345 channel width 345 mm 4 DHZ 5346 channel width 345 mm 5 DSZ 6200 channel width 260 mm 6 DSZ 5201 channel width 260 mm 7 DSZ 6240 channel width...

Page 12: ...pendent heat producing appliance is being operated Room air dependent heat producing appliances e g gas oil wood or coal operated heaters continuous flow heaters or water heaters obtain combustion air from the room in which they are installed and discharge the exhaust gases into the open air through an exhaust gas system e g a chimney In combination with an activated vapour extractor hood room air...

Page 13: ...formation GeneralinformationExhaust air mode Warning Risk of death Risk of poisoning from flue gases that are drawn back in The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms that contain heating appliances If the exhaust air is to be conveyed into a non functioning smoke or exhaust gas flue you must obtai...

Page 14: ... 3 mm Only an electrician may install the fixed connection We recommend installing a residual current circuit breaker RCCB in the appliance s power supply circuit 5Installation InstallationPreparing the installation Caution Ensure that there are no electric wires gas or water pipes in the area where holes are to be made 1 Mark a vertical centre line on the wall from the ceiling to the lower edge o...

Page 15: ...connector and seal Exhaust air pipe Ø 120 mm 1 Attach the reducing connector directly to the air pipe connector 2 Attach the exhaust air pipe to the reducing connector 3 Seal both joints appropriately Attaching the flue duct Warning Risk of injury From sharp edges during installation Always wear protective gloves while installing the appliance 1 Separate the flue ducts To do this remove the adhesi...

Page 16: ...961015 9001017124 9001017124 Robert Bosch Hausgeräte GmbH Carl Wery Straße 34 81739 München Germany www bosch home com ...

Reviews: