Bridge Name
: Type an optional name for the bridge in the
Bridge Name input box. This name facilitates recognition of
the bridge on the network.
–
IP Address
: Displays the current IP Address for the bridge.
Select option 2 to enter a new IP Address.
–
Subnet Mask
: Displays the current Subnet Mask for the
bridge. Select option 3 to enter a new Subnet Mask.
–
Default Gateway
: Displays the current Gateway Address
for the bridge. Select option 4 to enter a new Gateway
Address.
–
Recorder TCP Port
: Displays the TCP port number where
the recorder listens for the bridge device. You can type a
new port number in the input box.
–
Service TCP Port
: Displays the TCP port where the bridge
listens for CLI commands. (The bridge supports CLI
commands which are used to read and change settings in
the bridge). Select option 6 to enter a new port number.
–
Tx Server TCP Port
: Displays the TCP port number where
the bridge listens for the server that receives transaction
data from the POS or ATM devices on the network. Select
option 7 to enter a new port number.
–
Device Detection
: Enables or disables the Bridge
Detection utility to find the bridge on a network.
–
MAC Address
: Displays the MAC Address for the bridge.
This value cannot be changed.
NOTICE!
It is recommended to disable this feature once the network
settings are configured.
Summary of Contents for DVRXEAP01
Page 1: ...ATM POS Bridge DVRXEAP01 en Installation Manual ...
Page 2: ......
Page 42: ...42 en ATM POS Bridge F 01U 171 816 1 0 2010 09 Installation Manual Bosch Security Systems Inc ...
Page 43: ......
Page 44: ...Bosch Security Systems Inc www boschsecurity com Bosch Security Systems Inc 2010 ...