9 Other Information
9.1 Anti-Vandal Screws

After the cover has been installed and twisted into place, the entire 

assembly can be secured together using the supplied anti-vandal screws. 

Refer to the Top View of Enclosure in 

Figure 2.2 

for the location of the 

screw holes.

9.2 Maintenance

At least once a year, the range and coverage should be verified. To en-

sure continual daily operation, the end user should be instructed to walk 

through the far end of the coverage pattern. This ensures an alarm output 

prior to arming the system.

Bosch Security Systems

 B.V

. product manufacturing dates

Use the serial number located on the product label and refer to the Bosch 

Security Systems

 B.V. 

web site at: http://www.boschsecurity.com/datecodes/.

8 Supervision Features

The supervision features function as follows:

PIR/Microwave:  The complete circuit operation of these subsystems

is checked approximately every 6 hours. If the PIR or microwave

subsystem fails, the red LED will flash 4 times per cycle and the unit

should be replaced.

Default:  The detector will default to PIR technology protection if the

microwave subsystem fails.

MIN

MAX

Microwave

Adjustment

NOTICE!

Do not adjust the microwave range higher than required. Doing so 

may cause the detector to catch movement outside of the intended 

coverage pattern.

Figure 6.2: Adjusting microwave range

3. If adequate range can not be reached, increase the Microwave Range

Adjust slightly. Continue walk testing (waiting 1 minute after removing/

replacing the cover) and adjusting the range until the farthest edge of

desired coverage has been accurately placed.

4. Walk test the unit from all directions to determine all the detection

pattern boundaries.

Summary of Contents for DS9360

Page 1: ...tecodes 8 Fonctions de surveillance Les fonctionnalités de surveillance fonctionnent comme suit IRP hyperfréquences l intégralité du circuit de ces sous systèmes est vérifiée toutes les 6 heures environ En cas de défaillance du sous système IRP ou hyperfréquences la LED rouge clignote 4 fois par cycle et l appareil doit être remplacé Par défaut le détecteur passe en mode de protection IRP en cas d...

Page 2: ...rrent is required Alarm Relay Silent operating Form C relay Contacts rated 100 mA 25 VDC 2 5W 20 Ohm closed maximum for DC resistive loads Tamper Contacts rated at 28 VDC 125 mA maximum 1 Ohm To be connected to a SELV Safety Extra Low Voltage circuit only Connect tamper circuit to a 24 hour protection circuit Compliance This device complies with Part 15 of the FCC Rules Operation is subject to the...

Page 3: ...p the new module into place 4 Replace the enclosure onto the base 5 Close cover and turn clockwise to secure NOTICE Avoid fingerprints on the mirrored surfaces Should the mirrored sur faces become soiled or otherwise marked they can be cleaned using a soft clean cloth and any commonly available mild window cleaner 3 Wiring CAUTION Only apply power after all connections have been made and inspected...

Page 4: ...tivity mode 7 3 Microwave Adjustment NOTICE It is important to wait 1 minute after removing replacing the cover so the microwave portion of the detector can settle and to wait at least 5 seconds between the following walk testing procedures 1 The tri color LED should be off before walk testing 2 Walk test across the pattern at the intended coverage s farthest end Start walking from outside the int...

Page 5: ...Security Systems B V web site at http www boschsecurity com datecodes 8 Supervision Features The supervision features function as follows PIR Microwave The complete circuit operation of these subsystems is checked approximately every 6 hours If the PIR or microwave subsystem fails the red LED will flash 4 times per cycle and the unit should be replaced Default The detector will default to PIR tech...

Page 6: ...ntacts de valeurs nominales 100 mA 25 Vdc 2 5 watts 20 ohms fermés maximum pour charges résistives en courant continu Autosurveil lance Contacts de valeurs nominales 28 Vdc 125 mA maximum 1 ohm Doit être connecté au circuit très basse tension de sécurité TBTS uniquement Connectez le circuit d autosurveillance au circuit de protection 24 heures Conformité Cet appareil est conforme aux exigences imp...

Page 7: ... base 5 Fermez le couvercle et verrouillez le en le tournant dans le sens des aiguilles d une montre ATTENTION Évitez les traces de doigts sur les surfaces à miroir Si les surfaces à miroir sont sales ou portent des marques elles peuvent être nettoyées à l aide d un chiffon propre et doux et d un nettoyant de fenêtre doux quelconque 3 Câblage ATTENTION Mettez le dispositif sous tension uniquement ...

Page 8: ... conditions environnementales normales Le détecteur est réglé par défaut sur le mode Sensibilité élevée 7 3 Ajustement d hyperfréquences ATTENTION Il est important d attendre 1 minute après le retrait ou le remplacement du couvercle de façon à ce que la partie hyperfréquences du détecteur puisse s ajuster et d attendre au moins 5 secondes entre les procédures de test de détection suivantes 1 La LE...

Reviews: