Figure 2.2: Mounting 

Mounting Base

REAR WIRE

ENTRANCE

WIRE

TIE-DOWNS (2)

TERMINAL

STRIP

INTERFACE

PINS

MOUNTING

SLOTS (4)

1

8

LED

OFF  ON

I     H

LED and

LED Jumper

Sensitivity

Jumper

Microwave

Adjustment

LED

Wires

To

Cover

Top View of Enclosure

MIN

Anti-vandal Screw Hole

Anti-vandal Screw Hole

4. Firmly mount the base. Depending on local regulations, the base may

be directly surface mounted using anchors, mollies, or wing-nuts, or

may be mounted to standard 4-inch octagonal or square electrical

boxes.

NOTICE!

Be sure all wiring is de-energized before routing.

NOTICE!

The DS9360 base will not completely cover a 4-inch square box. Where 

aesthetics are important, a 4-inch octagonal box is recommended.

NOTICE!

Mounting to removable ceiling tiles is not recommended unless a 

sandwich is made of the base, ceiling tile, and a back plate behind the 

tile. Covers used for 4-inch octagonal and square boxes make a suitable 

back plate (when used with bolts and wing nuts, as an example).

5 Optical Module
5.1 Selecting the Optical Module

1. For ceilings between 8 and 13 ft. (2.4 and 4.0 m) from the floor, use

the optical module marked AR8-13. This marking can be found next to

the two optical module tabs.

2. For ceilings between 13 and 18 ft. (4.0 and 5.5 m) high, use the optical

module marked AR13-18.

3. To replace an optical module, push the optical module tabs towards

the center until the module snaps free of the circuit board. Holding the

new module by the tabs, snap the new module into place.

4. Replace the enclosure onto the base.
5. Close cover and turn clockwise to secure.

NOTICE!

Avoid fingerprints on the mirrored surfaces. Should the mirrored sur-

faces become soiled or otherwise marked, they can be cleaned using a 

soft, clean cloth and any commonly available, mild window cleaner.

3 Wiring

CAUTION!

Only apply power after all connections have been made and inspected.  

Do not coil excess wiring inside detector. Use no smaller than #22 

AWG (0.8 mm) wire in the terminal strip.

-

+

NO

C

NC

T

T

ALARM

TAMPER

POWER

+

-

TR

TROUBLE

Terminals 1 (-) & 2 (+):  Power contacts. 
Terminals 3 (NO), 4 (C), & 5 (NC):  Alarm relay contacts. Use terminals 4 

& 5 for Normally Closed circuits. Do not use with capacitive or inductive 

loads.
Terminals 6 (T) & 7 (T):  Normally Closed tamper contacts. 
Terminal 8 (TR): Solid state Trouble output. Shorts to ground (-) when the 

detector is in a Trouble condition.

Figure 3.1: Wiring to terminals

4 Coverage

360° by 60 ft. (18.3 m) diameter coverage when mounted on 8 to 18 ft

(2.4 to 5.5 m) high ceilings.

The coverage pattern consists of 64 zones grouped into 16 barriers,

with one additional zone looking straight down from the unit

(sabotage). Each barrier is 30 ft (9.2 m) long and 4.4 ft. (1.3 m) wide

at 30 ft (9.2 m).

The DS9360 comes with a choice of two optical modules. Refer to

Section 5.1 to determine the best module for on ceiling height.

9 m

8 m

6 m

4 m

2 m

0 m

2 m

4 m

6 m

8 m

9 m

30 ft

26 ft

20 ft

13 ft

7 ft

0 ft

7 ft

13 ft

20 ft

26 ft

30 ft

30 ft

26 ft

20 ft

13 ft

7 ft

0 ft

7 ft

13 ft

20 ft

26 ft

30 ft

≤5.5 m

≥4.0 m

4.6 m

0 m

≤4.0 m

3.0 m

≥2.4 m

0 m

9 m

8 m

6 m

4 m

2 m

0 m

2 m

4 m

6 m

8 m

9 m

0 ft

≥8 ft

10 ft

≤13 ft

0 ft

≥13 ft

15 ft

≤18 ft

AR13-18

AR8-13

9 m

8 m

6 m

4 m

2 m

0 m

2 m

4 m

6 m

8 m

9 m

Summary of Contents for DS9360

Page 1: ...tecodes 8 Fonctions de surveillance Les fonctionnalités de surveillance fonctionnent comme suit IRP hyperfréquences l intégralité du circuit de ces sous systèmes est vérifiée toutes les 6 heures environ En cas de défaillance du sous système IRP ou hyperfréquences la LED rouge clignote 4 fois par cycle et l appareil doit être remplacé Par défaut le détecteur passe en mode de protection IRP en cas d...

Page 2: ...rrent is required Alarm Relay Silent operating Form C relay Contacts rated 100 mA 25 VDC 2 5W 20 Ohm closed maximum for DC resistive loads Tamper Contacts rated at 28 VDC 125 mA maximum 1 Ohm To be connected to a SELV Safety Extra Low Voltage circuit only Connect tamper circuit to a 24 hour protection circuit Compliance This device complies with Part 15 of the FCC Rules Operation is subject to the...

Page 3: ...p the new module into place 4 Replace the enclosure onto the base 5 Close cover and turn clockwise to secure NOTICE Avoid fingerprints on the mirrored surfaces Should the mirrored sur faces become soiled or otherwise marked they can be cleaned using a soft clean cloth and any commonly available mild window cleaner 3 Wiring CAUTION Only apply power after all connections have been made and inspected...

Page 4: ...tivity mode 7 3 Microwave Adjustment NOTICE It is important to wait 1 minute after removing replacing the cover so the microwave portion of the detector can settle and to wait at least 5 seconds between the following walk testing procedures 1 The tri color LED should be off before walk testing 2 Walk test across the pattern at the intended coverage s farthest end Start walking from outside the int...

Page 5: ...Security Systems B V web site at http www boschsecurity com datecodes 8 Supervision Features The supervision features function as follows PIR Microwave The complete circuit operation of these subsystems is checked approximately every 6 hours If the PIR or microwave subsystem fails the red LED will flash 4 times per cycle and the unit should be replaced Default The detector will default to PIR tech...

Page 6: ...ntacts de valeurs nominales 100 mA 25 Vdc 2 5 watts 20 ohms fermés maximum pour charges résistives en courant continu Autosurveil lance Contacts de valeurs nominales 28 Vdc 125 mA maximum 1 ohm Doit être connecté au circuit très basse tension de sécurité TBTS uniquement Connectez le circuit d autosurveillance au circuit de protection 24 heures Conformité Cet appareil est conforme aux exigences imp...

Page 7: ... base 5 Fermez le couvercle et verrouillez le en le tournant dans le sens des aiguilles d une montre ATTENTION Évitez les traces de doigts sur les surfaces à miroir Si les surfaces à miroir sont sales ou portent des marques elles peuvent être nettoyées à l aide d un chiffon propre et doux et d un nettoyant de fenêtre doux quelconque 3 Câblage ATTENTION Mettez le dispositif sous tension uniquement ...

Page 8: ... conditions environnementales normales Le détecteur est réglé par défaut sur le mode Sensibilité élevée 7 3 Ajustement d hyperfréquences ATTENTION Il est important d attendre 1 minute après le retrait ou le remplacement du couvercle de façon à ce que la partie hyperfréquences du détecteur puisse s ajuster et d attendre au moins 5 secondes entre les procédures de test de détection suivantes 1 La LE...

Reviews: