12
Fixed installation:
The fixed installation can be carried out by a
qualified and authorized person only.
Envisage an omnipolar switch having a
contact opening of at least 3mm, including an
automatic circuit breaker.
The cable must be replaced by the
manufacturer, the assistance centre or a
qualified and authorized person only, in
order to avoid any dangers.
Electrical data:
The technical data of the device are on the
distinctive label inside the device behind the
grease filters.
In case of repair,
disconnect the electric
supply from the cooker hood.
Length of the feeding cable: 1,30m.
The hood complies with the EMC directives.
Installation
This extractor hood
is intended to be
mounted onto the kitchen wall.
WARNING!
Do not connect the
appliance to the mains until the installation is
fully complete.
Note:
Take into account any special
accessories that are going to be fitted.
1.
Remove the grease filter (refer to
Operating Instructions).
min.
600 Elektro
650 Gas
2.
Draw a line on the wall from the ceiling to
the lower edge of the hood at the centre
of the location where the hood is going to
be mounted.
3.
Using the template, mark positions on the
wall for the screws.
4.
Drill 2 holes (dia. 8 mm) for the extractor
hood.
Drill 2 holes (dia. 8 mm) for the bracket for
fixing the flue ducts - use the bracket as a
template: this should be fit close to the
ceiling so that index printed on the bracket
matches with the line previously marked
(see step 2).
Insert wall plugs flush with the wall.
Electrical connection