Power supply capacity calculation plan
How to start
Notice!
It is advisable to use the power calculation tool. The calculation tool is on the DVD supplied
with the Audio Powering Switch and is also part of the DICENTIS software DCNM.iso file,
which can be downloaded from the Bosch website at: https://licensing.boschsecurity.com/
software
Decide how to supply power to the DICENTIS devices:
–
Using the Audio Powering Switch and one or more Powering Switches.
–
Using one or more PoE Ethernet switches.
If you want to use PoE Ethernet switches, continue with chapter Calculation using PoE
switches, page 19.
See also
–
Calculation using DCNM-APS(2) or DCNM-PS(2), page 17
–
Installation material and tools, page 26
Calculation using DCNM-APS(2) or DCNM-PS(2)
Notice!
If you want to use customized cables, or a more accurate power supply capacity calculation
plan is needed, you should use the power calculation tool.
To calculate the total power supply capacity:
1.
Count all DICENTIS devices.
2.
Know the exact location where the devices are installed.
3.
Count each system network cable of the same length.
Device type
Power consumption (Watts)
DCNM-D
3.1
DCNM-DSL
3.6
DCNM-DVT
3.7
DCNM-DE
5.00
DCNM-MMD
11.30
DCNM-MMD2
12.00
DCNM‑CB02
1.19
DCNM‑CB05
2.43
DCNM‑CB10
4.50
DCNM‑CB25
10.71
Table 4.1: Power consumption (Watts)