DICENTIS

Conference System

 

 

en

Hardware Installation Manual

 

Summary of Contents for DICENTIS

Page 1: ...DICENTIS Conference System en Hardware Installation Manual ...

Page 2: ......

Page 3: ... 2 Redundant cabling for DCNM APS2 DCNM PS2 units 23 4 4 3 Redundant server PC 25 5 Installation material and tools 26 5 1 System Network Cable 26 5 2 System Cable Connectors 27 5 2 1 DCNM CBCON I Installation Cable Connectors 28 5 2 2 DCNM CBCON N Network Cable Connectors 28 5 3 DCNM CBTK System Network Cable Toolkit 29 5 4 DCNM CB250 System Installation Cable 30 6 Mechanical installation of Cent...

Page 4: ...disconnected mains supply Interventions with the equipment switched on are authorized only when it is impossible to switch the equipment off The operation must only be performed by qualified personnel Old electrical and electronic appliances Electrical or electronic devices that are no longer serviceable must be collected separately and sent for environmentally compatible recycling in accordance w...

Page 5: ... notice does not result in damage to the equipment or personal injuries Caution The equipment or the property can be damaged or persons can be lightly injured if the alert is not observed Warning The equipment or the property can be seriously damaged or persons can be severely injured if the alert is not observed Danger Not observing the alert can lead to severe injuries or death Copyright and dis...

Page 6: ...5 07 V1 3 4th edition New section 4 4 including sub sections 4 4 1 4 4 2 and 4 4 3 Sections updated 2 4 3 1 3 2 4 1 4 3 4 3 1 5 3 5 4 6 1 7 4 8 2015 11 V1 31 5th edition Sections updated 2 4 7 1 Terminology updated 2016 07 V1 4 6th edition Terminology updated DCN multimedia changed to DICENTIS Sections updated 3 1 3 2 4 1 4 3 1 4 3 2 4 4 1 4 4 2 4 4 3 5 3 5 4 7 1 7 2 7 3 7 4 8 2 4 6 en About this ...

Page 7: ...ily configured as a daisy chain configuration or as a star configuration Daisy chain configuration Uses dedicated cabling consisting of CAT 5e cables including two additional power conductors see Typical system setup page 8 Star configuration Each DICENTIS device is connected with an individual standard CAT 5e cable An Ethernet switch is also required for providing Power over Ethernet PoE Notice W...

Page 8: ...ce to contribute to a meeting 5 1 is a DICENTIS multimedia Device used for system power on off This device is always connected to the powered socket of the Audio Powering Switch or Powering Switch Note Only one DICENTIS multimedia Device should be connected here 5 2 is a DICENTIS device used via a Power over Ethernet PoE Ethernet switch Note Only one DICENTIS device should be connected here 6 Syst...

Page 9: ...does not give information on redundant network options For more information refer to Redundancy options page 21 DICENTIS System installation overview en 9 Bosch Security Systems B V Hardware Installation Manual 2016 09 V1 4 ...

Page 10: ...DICENTIS devices multiple subnets connected by use of a router L3 switch Each subnet can have up to 450 DICENTIS nodes Refer to the following table for the node count of DICENTIS equipment The first subnet has 1 DICENTIS Audio Powering Switch for the audio processing 1 Server PC which hosts the DICENTIS services 1 ARNI Enterprise to increase the size of the system All other subnets have 1 ARNI Sta...

Page 11: ...dresses For this reason Bosch advises to use 255 255 252 0 or 22 as a subnet mask This allows you to have 1018 IP addresses The following table lists the number of IP address per DICENTIS device in a DICENTIS Conference System Device IP addresses DICENTIS server optional Meeting Application 1 Client PC running DICENTIS meeting application 1 DICENTIS Audio Powering Switch 1 DICENTIS Powering Switch...

Page 12: ... because the power limitation will be reached before the max age restriction is reached The timer can be reached when you use cable redundancy the system is incorrectly wired 12 en System installation overview DICENTIS 2016 09 V1 4 Hardware Installation Manual Bosch Security Systems B V ...

Page 13: ...nected to the same subnet 192 168 64 x OMN ARNI E 192 168 64 1 VLAN64 192 168 65 254 Ports 1 2 3 4 L3 Switch VLAN66 192 168 67 254 Ports 5 6 7 8 VLAN74 internet 192 168 1 253 Ports 17 18 19 20 VLAN68 192 168 69 254 Ports 9 10 11 12 VLAN70 192 168 71 255 Internal DHPC server Ports 13 14 15 16 Internet Router 192 168 1 254 DCNM APS DCNM server PC DCNM PS DICENTIS devices Max 420 nodes DICENTIS devic...

Page 14: ...he DICENTIS Conference System and products System capabilities The capability of the DICENTIS Conference System and DICENTIS products depends on The lengths of the system network cables The number of connected devices The system power supply capacity Cable length System network cables DCNM CBxx lengths 2 5 10 or 25 m have a direct effect on the available power supply capacity The longer the system...

Page 15: ...r capacity of the system This makes the design and planning of the DICENTIS Conference System easier The calculation tool uses the power consumption of the devices and the system network cable lengths to calculate the needed system power supply capacity The calculation tool is on the DVD supplied with the Audio Powering Switch and is part of the DICENTIS software DCNM iso file The DCNM iso file ca...

Page 16: ...tch Hardware support for IGMP is strongly recommended Optional Rapid Spanning Tree support in case redundant networks are used Optional SNMPv3 support for switch supervision purposes Routers The following minimal requirements apply to routers 1 Gbit or higher Ethernet ports Supports PIM DM or Bidirectional PIM Performs IP routing in hardware i e a layer 3 switch to minimize the routing delay Packe...

Page 17: ...tion using DCNM APS 2 or DCNM PS 2 page 17 Installation material and tools page 26 Calculation using DCNM APS 2 or DCNM PS 2 Notice If you want to use customized cables or a more accurate power supply capacity calculation plan is needed you should use the power calculation tool To calculate the total power supply capacity 1 Count all DICENTIS devices 2 Know the exact location where the devices are...

Page 18: ...5 17 14 16 18 19 20 9 Figure 4 3 Powering Switch Item Description 1 5 XLR line outputs 1 and 2 2 6 RCA line outputs 1 and 2 3 7 XLR line inputs 1 and 2 4 8 RCA line inputs 1 and 2 9 Mains inlet mains switch and fuse holder 10 Reset button 11 Ground switch grounded or floating 12 Socket 1 without power 13 Socket 2 low power 18 en System installation design and planning DICENTIS 2016 09 V1 4 Hardwar...

Page 19: ...5 10 m cable DCNM DE 19x 2 m cable DCNM DE 4 5 5 19x 1 19 5 127 11 W2 1 For socket 2 the cable power consumption of the cable does not need to be counted if only one device is connected to this output 2 The shortest redundant cable does not need to be counted Calculation using PoE switches Select one or more PoE Ethernet switches to supply power to the DICENTIS devices Each DICENTIS device must be...

Page 20: ...2 2 1 Figure 4 5 Bottom view DICENTIS devices DCNM D DCNM DVT DCNM DSL DCNM DE Item Description 1 Network connector 2 Network PoE connector 20 en System installation design and planning DICENTIS 2016 09 V1 4 Hardware Installation Manual Bosch Security Systems B V ...

Page 21: ...ork cabling The following sections explain the redundancy options that can be used when designing your DICENTIS Conference System Each option can be combined in the DICENTIS Conference System providing you observe the redundant cabling limitations Refer to Redundant cabling for DCNM APS DCNM PS units page 22 Redundant cabling for DCNM APS2 DCNM PS2 units page 23 Redundant server PC page 25 Notice ...

Page 22: ...ing to the same DCNM APS DCNM PS type unit 1 DCNM APS or DCNM PS 2 DICENTIS devices 3 DICENTIS cabling redundant loop Cabling possibilities DCNM APS DCNM PS Limitations requirements Connect the DICENTIS devices in a daisy chain configuration from a high power socket on a DCNM PS or DCNM APS to another high power socket on the same DCNM PS or DCNM APS The redundancy is for cable only If the DCNM PS...

Page 23: ...length of the loop cable also consumes power The figure shows how to calculate the number of devices in the loop The red line shows the largest loop The sign shows the way the devices are counted In the example below up to 19 discussion devices can be connected 1 2 22 3 21 1 3 4 5 5 5 5 5 5 4 4 2 Figure 4 7 DICENTIS discussion devices connected with redundant cabling between DCNM PS2 DCNM APS2 typ...

Page 24: ...to create the daisy chain redundant loop For example high power socket 3 on one unit can be connected to high power socket 4 on another unit Note The redundant loop must be connected to another DCNM PS2 type unit You cannot use DCNM PS DCNM APS type units to create redundant loops for power You can create a redundant loop for signal only by connecting the DICENTIS devices in a daisy chain configur...

Page 25: ... shows the way the devices are counted In the example below up to 17 devices can be connected 4 20 2 3 21 22 1 1 1 4 4 5 5 5 3 2 2 Figure 4 8 Redundant DICENTIS server PC with redundant components and cables 1 DICENTIS system client PC 2 Network switch with optional redundant power supply 3 DCNM APS2 4 DCNM PS2 5 DICENTIS cabling redundant loop For this option to work the DICENTIS Conference Syste...

Page 26: ...cables DCNM CBxxx The minimum bend radius of the system network cable is 50 mm radius System Network Cable The system network cables terminated with connectors on both ends are available in different lengths and are used to connect DICENTIS devices to each other The cable consists of four CAT 5e twisted pairs to transmit data and two copper wires to supply the power Ordering number Cable lengths m...

Page 27: ...type of system cable 1 2 3 5 7 9 8 6 4 4 3 1 5 6 7 9 8 1 2 3 5 7 9 8 6 4 4 3 1 5 6 7 9 8 Figure 5 2 DCNM CBCON Front and exploded view Item Description 1 Strain relief boot 2 Ferrule 3 Plug connector shield 4 Power contacts Qty 2 5 Load bar 6 Power contact cavity 2 places 7 Housing 8 Locking latch 9 Signal contact cavity 8 Places See also System Network Cable page 26 DCNM CB250 System Installation...

Page 28: ... the DCNM CBTK System Network Cable Toolkit page 29 DCNM CBCON N Network Cable Connectors The DICENTIS 50 Network Cable Connectors DCNM CBCON N can only be used with the System Network Cable page 26 by using the DCNM CBTK System Network Cable Toolkit page 29 5 2 1 5 2 2 28 en Installation material and tools DICENTIS 2016 09 V1 4 Hardware Installation Manual Bosch Security Systems B V ...

Page 29: ...em Network Cable page 26 2 1 Item Description 1 Power wiring tool 2 Signal wiring tool Table 5 2 Toolkit content Notice Please consult the custom length for system network cables section on the DVD which can be downloaded at https licensing boschsecurity com software 5 3 DICENTIS Installation material and tools en 29 Bosch Security Systems B V Hardware Installation Manual 2016 09 V1 4 ...

Page 30: ...ion Cable Connectors page 28 and DCNM CBTK System Network Cable Toolkit page 29 Notice The maximum system network cable length is 100 m 328 9 ft Notice Please consult the custom length for system network cables section on the DVD which can be downloaded at https licensing boschsecurity com software See also System Cable Connectors page 27 5 4 30 en Installation material and tools DICENTIS 2016 09 ...

Page 31: ...tch are shipped with the following parts 1x Mains power cord 1x Safety instructions 1x Set of 19 inch mounting brackets 4x bottom feet 1x DVD containing manuals and software only with Audio Powering Switch Front view 1 2 2 1 3 Figure 6 1 Audio Powering Switch Powering Switch Item Description 1 19 mounting brackets 2 Ventilation inlet 3 Indication LED Off Switched off Green Switched on Amber Standb...

Page 32: ...ine inputs 1 and 2 9 Mains inlet mains switch and fuse holder 10 Reset button 11 Ground switch grounded or floating 12 Socket 1 without power 13 Socket 2 low power 15 17 19 Socket 3 4 5 high power 14 16 18 20 Overload LED for sockets 2 5 Green Power OK Red Overload Remove cable and wait a few seconds for the system to reset the overload 32 en Mechanical installation of Central Equipment DICENTIS 2...

Page 33: ... 3 Connect the mains supply 1 2 3 Figure 6 4 19 inch rack flat surface and feet mounting Item Description 1 19 inch rack mounting bracket 2 Flat surface mounting bracket 3 Feet mounting Notice The unit extends 30 mm in front of the 19 mounting brackets when installed in a 19 rack system Caution Do not obstruct the airflow vents on the front side and rear left and right sides DICENTIS Mechanical in...

Page 34: ...screen 2 LED strip 3 Two way loudspeaker 4 3 5 mm stereo jack for headphone or headset with integrated microphone 5 Headphone volume control 6 Microphone request button 7 Chairperson priority or microphone mute button 8 Near Field Communication NFC reader DCNM MMD2 only 9 Cable guides 10 Microphone input connector DCNM MMD2 is compliant with the Radio Equipment Directive RED 2014 53 EU Operating f...

Page 35: ...selection buttons 7 Language display 8 4 3 capacitive touch screen 9 3 5 mm stereo jack for headphone or headset with integrated microphone 10 Headphone volume control 11 Microphone input connector 12 Cable guides DCNM DE DCNM DVT and DCNM DSL are compliant with the Radio Equipment Directive RED 2014 53 EU Operating frequency is 13 56 MHz Maximum field strength is 8 4 dBµA m 10m DICENTIS Mechanica...

Page 36: ...ng for a neat tidy system installation especially advantageous for TV coverage To connect the system network cables to the DICENTIS devices refer to the following figure 1 Insert the system network cable connector 2 2 Lead the system network cable through the cable guides 3 Installing DICENTIS devices The DICENTIS devices can be free standing or fixed in more permanent installations using mounting...

Page 37: ...2x RJ45 connection input output for system power cable 3 Cable guides 4 USB connector for future use DCNM MMD DCNM MMD2 only See also System Network Cable page 26 DCNM CB250 System Installation Cable page 30 DICENTIS Mechanical installation of Contribution Devices en 37 Bosch Security Systems B V Hardware Installation Manual 2016 09 V1 4 ...

Page 38: ...CL front and bottom view Number Description 1 LED indicator 2 Microphone grill 3 Adjustable stem DCNM MICS DCNM MICL 4 Connection guidance 5 Slider guidance 6 Connector plug 7 Lock slider for lock release Press and shift to release 8 Lock 9 Device female connector see following figure 7 2 38 en Mechanical installation of Contribution Devices DICENTIS 2016 09 V1 4 Hardware Installation Manual Bosch...

Page 39: ...rophone connector 9 2 Gently push the connector plug 6 into the device microphone connector 9 until the connection lock 5 fits click into place 3 To remove the microphone from the device Shift lockslider 7 towards the device and hold in place lock release 8 and pull out the microphone See also DICENTIS devices page 34 DICENTIS Mechanical installation of Contribution Devices en 39 Bosch Security Sy...

Page 40: ...lm from the other side of the anti reflection foil 6 Lightly press the anti reflection foil on to the LCD screen If air bubbles are trapped under the anti reflection foil use the squeegee to remove them DCNM NCH Name Card Holder The name card holder 1 can be used to permanently display the participant s name on the rear of a DICENTIS multimedia Device The name card holder has two magnets 2 that al...

Page 41: ...een is shown 2 If the text Link down is shown The network cable is not connected or defective The device is only connected with one system network cable Link down is shown on the side where the device is not connected 3 If the system network cable is correctly connected to the network the network speed is shown 4 If the DICENTIS multimedia Device and the DICENTIS discussion Extended are connected ...

Page 42: ...ion manual on how to download the devices Customer service If a fault cannot be resolved please contact your supplier or system integrator or go directly to your Bosch representative 42 en Installation Test DICENTIS 2016 09 V1 4 Hardware Installation Manual Bosch Security Systems B V ...