22 / 40
ctrlX CORE
Dismounting the control
Bosch Rexroth AG
R911405645, Edition 03
NOTICE
Possible damage to property due to improper top-hat rail mounting
−
Fasten the top-hat rail adequately.
−
Connect the top-hat rail to a functional earth.
−
Mount the control on the top-hat rail, as the top-hat rail is also used for
heat dissipation and grounding.
−
Install the control in a control cabinet or an appropriate housing.
NOTICE
Control not fixed due to clamped top-hat rail mounting!
Before mounting, ensure that the top-hat rail mounting of the control is not in
opening position. If required, release the clamping of the opening position
using the locking lever, see
Fig. 10 “Locking lever to release the clamping of
the opening position” on page 22
.
Fig. 10: Locking lever to release the clamping of the opening position
10.4 Dismounting the control
To dismount, use a common tool such a slotted screwdriver with a 2.5 mm blade.
10.4.1 Dismounting steps
NOTICE
Destruction of components and devices due to mounting and dismounting
under voltage!
−
Before mounting or dismounting, disconnect the control - including its
components - from voltage.
−
Connect the voltage only after the control and its components have been
set up.
For a secure decommissioning with regard to the IT security, refer to