Conettix DX4020
|
Installation Guide | Trademarks
.
Bosch Security Systems, Inc. | 1/09 | F01U045288-05
3
Trademarks
•
Microsoft
®
and Windows
®
are either registered
trademarks or trademarks of Microsoft
Corporation in the United States and/or other
countries.
•
Lantronix
®
is a registered trademark of Lantronix
Corporation, registered in the U.S. and other
countries.
•
XPort
™
with its patent-pending technology is a
trademark of Lantronix, Inc.
UL Requirements
For Underwriters Laboratories, Inc. (UL)
Listed fire Installations, ensure that the
shared on-premises communications
equipment is UL Listed for information
technology equipment.
1.
Set the parameters in the RADXAUX1 or
GV2AUX section of the control panels
(
Table 1
).
The GV2AUX handler is used for GV2
Series control panels. The RADXAUX1
handler is used for G Series control panels.
Table 1:
Control Panel RADXAUX1 or GV2AUX
UL Parameters
Control Panel on Protected Premises
1
UL1610 Line Security
Intrusion System
Installations
RADXAUX1
GV2AUX
Parameter
No Digital
Dialer
Backup
Digital
Dialer
Backup
UL864 Fire
Systems
Installations
2
Poll Rate
75 sec
240 sec
75 sec
ACK Wait
13 sec
13 sec
13 sec
Retry Count
5
5
5
1 For local annunciation, G Series control panels require
Firmware Version 6.9 or higher. GV2 Series control panels
require Version 7.04 or later.
2
Install the system according to NFPA-72.
2.
Add a Telnet password to the DX4020
communications protocol. To complete the
configuration, refer to
Section 6.5 Using Telnet to
Complete Configuration
, page 11.
Keep your password for future reference.
Certifications and Approvals
UL Standards
•
UL294, Access Control Systems Units
•
UL864, UL Commercial Fire Alarm signaling
•
UL365, Police Station Burglar Alarm Units and
Systems
•
UL609, Local Burglar Alarm Units and Systems
•
UL985, Household Fire Warning System Units
•
UL1023, Household Burglar-alarm System Units
•
UL1076, Proprietary Burglar Alarm Units and
Systems
•
UL1610, Central Station Burglary, Line Security
ULC Standards
•
CAN/ULC-S303-M91, Local Burglar Alarm Units
and Systems
•
CAN/ULC-S304-M88, Central and Monitoring
Station Burglar Alarm Units
•
CAN/ULC-S545, Residential Fire Warning System
Control Units
•
ULC/ORD-C1076-M1986, Proprietary Burglar
Alarm Units and Systems Communicator
•
ULC-C1023-1974, Household Burglar Alarm
Systems
Approvals
•
•
CSFM
•
NF A2P Type 2 Certification number:
122000076-05
•
FM*
* When used with the Conettix D6600
Communications Receiver/Gateway.
Refer to the
D6200 Software Operation
and Installation Guide
(P/N: 4998154991)
to configure the D6600/D6100i
Communication Receiver/Gateway to
receive UL Listed communications from a
DX4020.