CCS800 |
Service manual | Chapter 7 | Diagnostics and faultfinding
en | 34
Bosch Security Systems | 2005-01| 3922 880 21112
7.3.15
AUDIO CONTROL IN to LINE-OUT via AFS circuit of CPSU measurement
(LBB 3310/10 only)
Connect a sine-wave generator to one Trunk connectors (X2) M1 and measure the output signal at output LINE-OUT
(M119).
•
Set AFS switch (S4) to position ‘On’.
•
Connect on CPSU board X10-3 (audio out) to X10-5 (audio in). AFS board is not required for this test.
Input setting G1: X11 p-1 related to M2 (GND), see table below.
settings for G1
measurement results for A1
Amplitude
Frequency
Amplification
Nominal level
-28dBV (39.8mV
rms
)
1 kHz
-14dBV ± 2dB (85dB SPL)
Maximum level
-3dBV (794mV
rms
)
1 kHz
+11dBV ± 2dB (110dB SPL)
Bandwidth
-28dBV (39.8mV
rms
)
125 Hz
-0.5dB ± 1dB related to nom. level at 1kHz
Bandwidth -28dBV
(39.8mV
rms
)
12.5 kHz
-1dB ± 1dB related to nom. level at 1kHz.
•
Set AFS switch (S4) to position ‘Off’.
Reference:
X10, 12
See Ch. 13.6
X2
See Ch. 13.7