![Bosch CCS800 Service Manual Download Page 29](http://html.mh-extra.com/html/bosch/ccs800/ccs800_service-manual_46525029.webp)
CCS800 |
Service manual | Chapter 7 | Diagnostics and faultfinding
en | 27
Bosch Security Systems | 2005-01| 3922 880 21112
7.3.8
Telephone-out, Line-out and Insertion-out measurement
Connect a sine-wave generator to the LINE-IN connector and measure successively the output signal at the
TELEPHONE-OUT (M109), LINE-OUT (M119) and INSERTION-OUT“ (M169) connector.
Input setting G1: M110 related to M111 (GND), see table below.
Settings for G1
Measurement results for A1
Amplitude
Frequency
Amplification
Nominal level
-14dBV (200mV
rms
)
1kHz
-14dBV ± 1dB (85dB SPL)
Maximum level
+11dBV (3.55V
rms
)
1 kHz
+11dBV ± 1dB (110dB SPL)
Bandwidth
-14dBV (200mV
rms
)
125 Hz
-0.5dB ± 2dB related to nom. level at 1kHz
Bandwidth -14dBV
(200mV
rms
)
12.5 kHz
-1.0dB ± 1dB related to nom. level at 1kHz.
Reference:
M169
See Ch. 13.5
M109, 119
See Ch. 13.6