6 720 646 812
Maintenance and service
45
6.6
Program values
This section describes details on programming the
appliance. For most applications the factory default val-
ues will provide robust and stable operation. Only
adjust the factory settings if the installation requires
changes as indicated in the appropriate section of this
manual.
Refer to 6.7 Control board diagnostics (page 35)
regarding how to access these P-modes.
Caution:
Misadjusted
program
values can lead to appliance
malfunction, errors, and service
calls.
Program
Description
Factory Default
MIN
MAX
Comment
P1
Maximum Power
NG: 46,
LP: 46
21
NG: 48,
LP: 48
see chapter 3.14, page 35
note: reducing P1 values below
maximum will reduce maximum
power of the appliance.
P2
Minimum Power
13
12
20
see chapter 3.3.7, page 20
P3
Remote
Controls installed
_0
_0
6
see chapter 5.5, page 39
P4
Access to
Diagnostic Mode
E
0d
10f
see chapter 6.7, page 46
P5
Cascade Mode
NO
NO
CC
contact Bosch for details
P6
Temperature Unit
°F
°F
°C
P7
Appliance Type
Cd
Cd
NO
Condensing / Non-condensing
note: incorrect setting will cause
errors.
P9
Fan Purge
runs secondary fan and primary
fan when P9 is selected by
depressing the “P” - button
PH
Cascading type
IC
IC
SC
This menu is only available when
cascade mode is selected CC.
Contact Bosch Water Heating
for details.
PC
Master/Slave
mode
CS
CS
CM
Table 25 Program values, factory default settings and ranges.
Summary of Contents for C1050ES
Page 56: ...6 720 646 812 56 Functional scheme 11 Functional scheme Fig 76 Functional scheme ...
Page 58: ...6 720 646 812 58 Interior components diagram and parts list Fig 78 Appliance overview ...
Page 69: ...6 720 646 812 Notes 69 15 Notes ...
Page 70: ...6 720 646 812 70 Notes ...