19
Installation Instructions
Bosch Climate 5000 Series Wall Mounted Ductless Split Air Conditioner / Heat Pump (06.2022)
Step 3: Anchor outdoor unit
The outdoor unit can be anchored to to a commercially available mounting pad on
the ground or to a wall-mounted bracket (both sold separately).
Unit mounting dimensions
The following is a list of diff erent outdoor unit sizes and the distance between their
mounting feet. Prepare the installation base of the unit according to the dimensions
below.
NOTICE: PROPERTY DAMAGE/SYSTEM FAILURE
Never mount this unit directly on the ground. It must be
anchored according to the guidance provided in these
instructions, and/or local building codes.
Outdoor Model
Outdoor Unit Dimensions mm (in)
Mounting Dimensions
W x H x D
Distance A mm (in)
Distance B mm (in)
BMS500-AAS012-0CSXRC, BMS500-AAS009-1CSXRC
BMS500-AAS012-1CSXRC
765x555x303 (30.1”x 21.8”x 11.9”)
454 (17.8”)
286(11.3”)
BMS500-AAS009-1CSXHC, BMS500-AAS012-1CSXHC
805x554x330 (31.7”x 21.8”x 13.0”)
511 (20.1”)
317(12.5”)
BMS500-AAS018-1CSXRC, BMS500-AAS018-1CSXHC
BMS500-AAM018-1CSXRC
890x673x342 (35.0”x 26.5”x 13.5”)
663 (26.1”)
348 (13.7”)
BMS500-AAS030-1CSXRC, BMS500-AAS036-1CSXLC
BMS500-AAS036-1CSXRC, BMS500-AAS024-1CSXRC
BMS500-AAS024-1CSXHC, BMS500-AAM027-1CSXRC
BMS500-AAM036-1CSXRC, BMS500-AAM018-1CSXHC
BMS500-AAM027-1CSXHC
946x810x410 (37.2”x 31.9”x 16.1”)
673 (26.5”)
403 (15.9”)
BMS500-AAS060-1CSXLB, BMS500-AAS048-1CSXLC
BMS500-AAM048-1CSXRC, BMS500-AAM036-1CSXHC
BMS500-AAM048-1CSXHC
952x1333x415 (37.5”x 52.5”x 16.34”)
634 (25.0“)
404 (15.9”)
Table 3
Figure 23
Outdoor Unit