Installation Instructions
Bosch Climate 5000 Series Wall Mounted Ductless Split Air Conditioner / Heat Pump (06.2022)
7.
Firmly hold the refrigerant piping at the base of the bend.
8.
Carefully, with even pressure, bend the piping towards the hole. Do not kink
or damage the piping during the process.
If refrigerant piping is already embedded in the wall, do the following:
1.
Hook the top of the indoor unit on the mounting plate.
2.
Open and fi x the position of the panel, then, open the covers of the two lock
blocks, unscrew the screw showed in the picture below, then hold both sides
of the lower panel in the place marked “PULL”, pull it upwards to release the
buckles, then take the lower panel down.
Figure 12
Open the cover
and unscrew the
screw
AUTO COOL
3.
Use a bracket or wedge to prop up the unit, giving you enough room to
connect the refrigerant piping, signal/power cable, and drain hose. Refer to
Figure 13 for an example.
Figure 13
4.
Connect drain hose and refrigerant piping (refer to Refrigerant Piping
Connection section of this manual for instructions).
5.
Keep pipe connection point exposed to perform the leak test (refer to
Electrical Checks and Leak Checks section of this manual).
6.
After the leak test, wrap the connection point with insulation tape.
7.
Remove the bracket or wedge that is propping up the unit.
8.
Using even pressure, push down on the bottom half of the unit. Keep
pushing down until the unit snaps onto the hooks along the bottom of the
mounting plate.