42
en | RADION repeater
RADION receiver SD
2020.05 | 13 | F.01U.261.834
Bosch Security Systems B.V.
7.
Make sure all other devices operate and report correctly,
and have good signal strength.
This concludes the redundant communication verification
process.
4.1
Installation considerations
Use the provided anchors and screws to mount the repeater in
locations accessible for future maintenance. Mount the repeater
onto a wall.
Notice!
Mount the repeater in a location removed from metal. Metal
objects (duct work, wire mesh screens, boxes) reduce RF range
4.2
Wiring considerations
Notice!
Do not install long cable runs next to high-current power feeds.
Keep cable lengths as short as possible to minimize noise
pickup.
Ensure that the wiring used meets the following specifications:
–
Two-conductor unshielded wire.
–
The minimal requirement for wire length is 1.83 m (6 ft)
from the repeater
4.3
Specifications
Dimensions
139.70 mm x 209.60 mm x 31.80 mm
(5.50 in x 8.25 in x 1.25 in)
Compatible plug-in transformers for use with the RFRP-A
repeater within US installations:
These transformers are approved by UL: