Notice!
For UL installations when transformer is used, restraining tab is
to be connected.
Notice!
For UL installations when a repeater is installed, a minimum of
two repeaters must be installed for proper signal routing.
Information related to the internal standby battery is as follows:
–
Power/voltage (Standby Battery): Rated 3.7 VDC,
3050mAH, EVE ENERGY CO Part No P0046-LF (Not user
replaceable)
Notice!
For standby battery to be operative, the tamper switch is
required to be engaged.
Standby battery is capable of providing 72 hours of standby
power to the RF repeater for a UL Burglar Alarm Installation
(Bank Safe and Vault).
–
24 Hours for Household Fire Warning Systems
–
8 Hours for HOLD UP Burglar Alarms
–
4 Hours for Burglar Alarm Mercantile Installations