173_58300000002379_ara_en_j.doc – 29.04.14
Seite 32 von 41
2.19 Filler neck on the compressor too short
On some fridge-freezers the filler necks on the compressor are
pinched off ex works instead of the soldered filler pipe as is usually
the case. When the refrigeration circuit is opened, the refrigeration
circuit cannot therefore be filled via the filler neck, as the compressor
filler pipe and the customer service filler pipe cannot be connected
with a Lokring.
If a replacement compressor is used, the filler pipe can be attached as
usual.
To fill the refrigeration circuit, a Lokring T-piece with valve must be
installed on the suction side. The refrigeration circuit is then
evacuated and filled via the valve.
Lokring T-piece with valve
6/6 material no. 00066020
8/6 material no. 00066030