173_58300000002379_ara_en_j.doc – 29.04.14
Seite 3 von 41
2
THEMES VON A – Z
2.1 Condensation tray flows over
Condensation trays can overflow without visible mechanical failure
(loose or defect door gasket, etc.).
Solution:
In this case a self-adjusting heater has to be installed. This heater
assists the evaporation at a high water-level.
Spare part-No.:
00753407
The assembly has to be done according to the spare part information.
Please be sure that the heater is connected parallel to the power
supply.
Function:
If water completely surrounds the heater, the temperature and the
resistance decrease.
Heater heats
If no water surrounds the heater, the temperature and the resistance
increase.
heater stopps heating
Overview heater
Temperature in ºC
resistance in K
Ω tol/-30%
20 ºC
1,7 K
Ω
30 ºC
2,3 K
Ω
40 ºC
3,4 K
Ω
50 ºC
6,2 K
Ω
60 ºC
20,5 K
Ω