50
en | Installing the Roof Parapet and Pipe Mounts
AUTODOME IP starlight 7000i
2021-03 | 1.2 |
Installation Manual
Bosch Security Systems
Pin Description
Pin
Description
Pin
Description
1
Alarm Out 1
1
Alarm in 3
1
Alarm Out 4 Normally Open
2
Alarm Out 2
2
Alarm in 4
2
Alarm Out 4 COM
3
Alarm Out 3
3
Alarm in 5
3
Alarm Out 4 Normally Closed
4
Alarm Ground
4
Alarm in 6
4
Earth Ground
5
Alarm in 7
5
Analog Alarm 1
6
Alarm Ground
6
Analog Alarm 2
7
Ground
For in-ceiling mount only: Low Voltage TTL (3.3V) can also be used.
4
Connect the plugs to their mating connectors P103 and P102 on the Pipe Interface
Board.
1.
To connect supervised alarms and relays, attach the appropriate wires to their terminals
on the P104 connector on the Pipe Interface Board (see above).
2.
Insert the Pipe Interface Board into the down pipe and fasten the three (3) retaining
screws to secure the board to the Dome Cap.
!
Caution!
Be careful not to strip the threads when tightening the Pipe Interface Board retaining screws.
Figure 10.8:
Pipe Interface Board to Dome Cap Assembly
1
Interface Board
2
Retaining Screws (3)
3
Pendant Mounting Screws (2)