Time range: If you select this option, then two input fields appear to the right. In these
fields, enter the time range for the activation of the alarm in hours and minutes. (The
default values are 00:00 and 00:01.)
Select one of the following output commands for both Output 1 and Output 2 settings:
Note: Not all options are available for all cameras.
–
None
: no defined command.
–
AUX on
: defines a standard or custom keyboard ON command.
–
AUX off
: defines a standard or custom keyboard OFF command.
–
Pre-position
: defines a pre-position from shot 1-256. (Note: This option is not available
for the input
Time range
.)
The table below identifies the Input and Output options and the additional fields that appear
depending on the options selected.
Field
Value
Additional Input
field
Additional
Output field
NOTES
Input
Alarm input
Day/night
IVA/
Connection
Time
Time range
1: Input 1
2: Input 2
00:00
00:00 00:00
Output 1 /
Output 2
None
Alarm output
AUX on / AUX off
Pre-position
1: Output 1
1: Scan 360°
7: Custom tour
8:
Pre-position
tour
18: Auto pivot
57: Night mode
60: On-screen
display
67: IR focus
correction
80: Digital zoom
Scene 1
Scene 2
Not available as an
Output if Input is
“Time range”.
(Refer to the “AUX Commands” section of the manual for a list of all AUX commands for your
camera.)
Click the checkbox
Enabled
to activate the alarm.
Click Set to save. The camera’s system activates the alarm rules.