3.
Check the box in the Rec. 1 or Rec. 2 column to specify the recording tracks to be
recorded on the target selected.
Formatting storage media
All recordings on a storage medium can be deleted at any time. Check the recordings before
deleting and back-up important sequences on the computer's hard drive.
1.
Click a storage medium in the Managed storage media list to select it.
2.
Click Edit below the list.
3.
Click Format in the new window to delete all recordings in the storage medium.
4.
Click OK to close the window.
Deactivating storage media
A storage medium in the Managed storage media list can be deactivated. It is then no longer
used for recordings.
1.
Click a storage medium in the Managed storage media list to select it.
2.
Click Remove below the list. The storage medium is deactivated and removed from the
list.
Recording Profiles
A recording profile contains the characteristics of the tracks that are used for recording. These
characteristics can be defined for ten different profiles. The profiles can then be assigned to
days or times of day on the Recording Scheduler page.
Each profile is color-coded. The names of the profiles can be changed on the Recording
Scheduler page.
To configure a profile click its tab to open its settings page.
–
To copy the currently visible settings to other profiles, click Copy Settings. A window
opens to select the target profiles for the copied settings.
–
If you change a profile’s settings, click Set to save.
–
If necessary, click Default to return all settings to their factory defaults.
Stream profile settings
Select the encoder profile setting that is to be used with stream 1 and 2 when recording. This
selection is independent of the selection for live stream transmission. (The properties of the
encoder profiles are defined on the Encoder Profile page.)
Recording includes
You can specify whether, in addition to video data and metadata (for example alarms, VCA
data and serial data) should also be recorded. Including metadata could make subsequent
searches of recordings easier but it requires additional memory capacity.
!
Caution!
Without metadata, it is not possible to include video content analysis in recordings.
Standard recording
Here you can select the mode for standard recordings.
If you select Continuous, the recording proceeds continuously. If the maximum memory
capacity is reached, older recordings will automatically be overwritten. If you select the Pre-
alarm option, recording will only take place in the pre-alarm time, during the alarm and during
the set post-alarm time.
7.1.4
7.1.5
7.2
AUTODOME IP 4000 HD / AUTODOME
IP 5000 HD/IR
Recording | en
35
Bosch Security Systems
Operation Manual
2016.04 | 0.4 |
Summary of Contents for Autodome IP 4000 HD
Page 1: ...AUTODOME IP 4000 HD AUTODOME IP 5000 HD IR en Operation Manual ...
Page 2: ......
Page 58: ......
Page 59: ......