AutoDome Easy II IP
Preparing the Wiring | en
67
Bosch Security Systems, Inc.
Installation Manual
F.01U.164.576 | 2.0 | 2010.03
8.2.3
Power Connections to Heater (all outdoor models)
Figure 8.3
Power Cable
To connect the power to outdoor heaters:
1.
Locate the cable assembly with a three (3) pin mating
connector on one end and the white/red and white/black
flying leads on the other end.
2.
Connect one lead of the ground or 24 VAC power source to
the white/black wire.
3.
Connect one lead of the 24 VAC power source to the
white/red wire.
8.3
Ethernet Connection (IP models)
The AutoDome Easy II IP connects to a 10 Base-T/100 Base-TX
network either directly or via a hub. Both video and control are
transmitted over a standard TCP/IP network using the built-in
Web server. In addition, power can be supplied to indoor IP
camera models via the Ethernet cable compliant with the
Power-over-Ethernet (IEEE 802.3af) standard.
Refer to
Section 11 Using the AutoDome Easy II IP, page 74
, for
instructions on configuring an IP environment.
Ref. # Wire
Color
1
24 VAC
White/Red
2
24 VAC
White/Black
3
User supplied Power Supply
n/a
WARNING!
The heater unit accepts 24 VAC, 2 A power only. Do not connect
120 V or 230 V to this heater.
CAUTION!
Ethernet connections must be made to non-exposed (indoor)
networks only.
Summary of Contents for AutoDome Easy II IP