Figure 8.12: Control panel configuration - System options
Direct Connection
The direct connection function allows establishing a connection from the remote PC to AMAX
panel 4000 via USB to perform remote programming and control.
The remote PC should have installed remote programming software like A-Link Plus. Customer
should install "USB driver" first. This installation will create an additional COM device on the
PC. When finished installation, identify the COM-Port associated to this device.
Start A-Link Plus application and login with customer: admin pw: ADMIN. Select Menu item
File – Communication Settings.
8.6.1
AMAX panel 4000 / AMAX panel 4000
EN
Configuration | en
93
Bosch Sicherheitsysteme GmbH
Installation Guide
2013.07 | 03 | F.01U.267.112