When no callback from the receiver after the acknowledge time is reached, the control panel
takes it as an unsuccessful communication and makes another attempt. The time ranges from
5 to 99 sec.
Contact your central monitoring station for the correct setting.
Network Polling Time
The polling is used for both panel and remote receiver to know whether the network
connection is good or not. Each time when a polling is due, the control panel will send a
polling message. The polling time range is from 1 to 999 minutes. For time less than 3 digits,
use 0 to fulfil.
Contact your central monitoring station for the correct setting.
Dual IP
Dual IP Settings are valid only when used with Conettix IP communication format. IP module 1
is ITS-DX4020-G module or B426 module; IP module 2 is B426 module. IP module 2 does not
support RPC connection.
When the report is transmitted with Conettix IP Communication, some reports might be
missed. It is recommended not to separately use ITS-DX4020-G module. If ITS-DX4020-G
module is used, other network modules (e.g. B426) or the public telephone network can be
set as backup channel to ensure no reports are missed.
The communication path of B426/ITS-DX4020-G is as follows:
Module
Address Setting
Corresponding
Communication Path
Module 1: B426 module 1/ITS-
DX4020-G
134
Paths 1 and 2
Module 2: B426 module 2
250
Paths 3 and 4
When IP module 1 is used only and set to send to paths 1 to 4, the report can be sent to paths
1 to 4.
7.1.5
38
en | Settings
AMAX panel 4000 / AMAX panel 4000
EN
2013.07 | 03 | F.01U.267.112
Installation Guide
Bosch Sicherheitsysteme GmbH