Video Recorder 600 Series
Configuration menu | en
61
Bosch Security Systems
Installation and Operation manual
F.01U.169.663 | v1.0 | 2010.09
6.4
Event
Use the
Event
menu to specify the desired behavior for an Input, detected Motion, or System
failures; also define how alarms are acknowledged.
6.4.1
Input
Figure 6.12
Event - Input
Inputs are always active on the unit.
Note:
For 16-channel units, use the
ch09 to ch16
or
ch01 to ch08
button to display the required
input.
Input Type
The Event behavior can be configured independently for each channel.
–
N.O.
- Normally Open causes an alarm to trigger only when the circuit closes
–
N.C.
- Normally Closed causes an alarm to trigger only when the circuit is opened
Camera
Set the camera between 1 and 8/16, which is set to an alarm based on the input.
Relay output
Select the relay to trigger in response to the input.
PTZ
–
For the camera associated with the input, a
PTZ preset
can be sent to the camera to
move to a specified pre-position.
–
Enter a pre-position number from
1-255
for each of the PTZ cameras that should be
moved.