LTC 2600 Series
| Instruction Manual
|
Multiplexer Read (MR) Commands
Bosch Security Systems | July 12, 2004
EN
| 33
MR-OPERATION-DUPLEX
This command returns the operating modes for duplex
multiplexer models.
Returned parameter values are:
<mode-D1>
1
Monitor A - live digital
2
Monitor A - playback
3
Record ON - System4
models only
<mode-D2>
0
Record OFF
1
Record ON
MR-PASSWORD
This command returns the multiplexer password.
Returned parameter values for <password> are
<digit><digit><digit><digit> where <digit> equals
any number between 0 and 9.
MR-SEQ-DWELL
<monitor> <mon-mode>
This command returns the sequence dwell time for the
specified monitor in the specified display mode.
Parameter values are:
<monitor>
1
Monitor A
2
Monitor B
<mon-mode>
1
Full screen mode
2
Quad mode
<dwell-time>
0
Sequence disabled
(returned value) 1-60
Dwell time in seconds
MR-SEQ-DWELL-TIME
<seq-device>
This command returns the sequence dwell time for the
specified monitor in the specified display mode (<seq-
device>).
Parameter values are:
<seq-device>
1
Monitor A - Full screen
2
Monitor A - Quad
3
Monitor B - Full screen
4
Monitor B - Quad
<dwell-time>
0
Sequence disabled
(returned value) 1-60
Dwell time in seconds
MR-SEQ-ENABLE
<monitor>
This command returns the setting (enabled/disabled
sequencing) for the specified monitor if its display
mode is Full or Quad.
Parameter values are:
<monitor>
1
Monitor A
2
Monitor B
<boolean>
0
Disabled sequencing
(returned value) 1
Enabled sequencing
MR-SEQ-LIST
<monitor> <display-mode>
This command returns the camera list being sequenced
in the specified mode on the specified monitor.
Parameter values are:
<monitor>
1
Monitor A
2
Monitor B
<display-mode> 0
Full screen
1
Single quad
2
3x3 multi
3
4+3 multi
4
12+1 multi
5
4x4 multi
6
8+2 multi
<camera list>
A list of camera numbers
(returned value)
(1-32) given in the order
desired for the
sequence/display