LTC 2600 Series
| Instruction Manual
|
Multiplexer Set (MS) Commands
Bosch Security Systems | July 12, 2004
EN
| 23
MS-TIME-EVENT-STATUS
<start-item> <end-item>
<status>
This command allows you to enable or disable
individual time-events. A range of time-events can also
be enabled/disabled by specifying different start and
end item parameters.
Parameter values for <start-item> , <end-item> , and
<status> are:
<start-item> 1 to 64 (time-event reference#)
<end-item> 1 to 64 (time-event reference#)
<status>
0
Disable
3
Active (Enable)
MS-VCR-ACTION-RECORD
<vcr> <record mode>
This command sets the VCR response to an action.
Parameter values for <vcr> and <record mode> are as
follows:
<vcr>
1
VCR output
2
VCR/Monitor B output
<record mode> 0
OFF
1
Exclusive (records only the
action cameras)
2
Interleave (records the action
cameras in addition to the
cameras specified by the MS-
VCR-RECORD-LIST
MS-VCR-ALARM-RECORD
<vcr> <record mode>
This command sets the VCR response to an alarm.
Parameter values for <vcr> and <record mode> are as
follows:
<vcr>
1
VCR output
3
VCR/Monitor B output
<record mode> 0
OFF
3
Exclusive (records only the
alarm cameras)
4
Interleave (records the alarm
cameras in addition to the
cameras specified by the MS-
VCR-RECORD-LIST
MS-VCR-CUSTOM
<custom-vcr-model#> <vcr-
mode> <hour-rate>
<field-rate-MSB> <field-rate-LSB> <play-times>
This command sets the parameters for custom VCR
definition.
Parameter values are as follows:
<custom-vcr-model#>
1 to 6 (corresponding to
custom VCR setting 1 to 6)
<vcr-mode>
1 to 20
<hour-rate>
<field-rate-MSB>
<field-rate-LSB>
<play-times>
0
SP
1
LP