![Bosch 2000 Series Program Entry Manual Download Page 54](http://html.mh-extra.com/html/bosch/2000-series/2000-series_program-entry-manual_39237054.webp)
2000 Series |
Program Entry Guide | 13.0
Relays
EN
| 54
Bosch Security Systems | 7/05 | 35114F
Table 18: Relay Function Selections
Programmers Keypad
Description
No Output
0
No output at the relay terminal.
Alarm
1
Provides a steady output when a point is in an alarm condition.
The relay output follows
Bell Time
.
Note:
This output does not occur for alarms caused by A, B, C Keys.
Entering a combination to acknowledge an alarm resets the relay.
Select the points to monitor for alarms at the
Parameter
prompt.
Alarm Memory
2
Provides a steady output when a point shows alarm memory at the keypad.
Turning the system on clears alarm memory and ends the output.
This output
does not occur for alarms caused by A, B, C Keys.
Select the points to monitor for alarm memory at the
Parameter
prompt.
Point Trouble
3
Provides a steady output when selected points are in trouble.
Select the points to monitor for troubles at the
Parameter
prompt. Swinger
bypass is a point trouble and activates the Point Trouble Relay function.
Follow Point
4
Provides a steady output when selected points are faulted (including point trouble
and alarm).
Select the points to monitor for faults at the
Parameter
prompt.
Watch Tone
5
Activates the relay output in parallel to the watch tone for selected points. Refer to
Key 7, Watch Tone in the User’s Guide. If you set the watch tone to No Tone, the
Watch Tone relay does not activate. Select the points for Watch Tone monitor at
the
Parameter
prompt.
A,B,C Key, Steady
6
Activates the relay output when a user presses a selected function key. The relay
output remains activated until a user performs a System Reset (presses [3] and
enters a passcode).
Select the function keys to monitor at the
Parameter
prompt.
A,B,C Key, Pulse
7
Activates the relay output when a user presses a selected function key. The relay
output pulses until a user performs a System Reset (presses [3] and enters a
passcode).
Select the function keys to monitor at the
Parameter
prompt.
Summary of Contents for 2000 Series
Page 1: ...EN Program Entry Guide Control Panels 2000 Series ...
Page 14: ...2000 Series Program Entry Guide 3 0 Reports EN 14 Bosch Security Systems 7 05 35114F Notes ...
Page 26: ...2000 Series Program Entry Guide 6 0 Open Close EN 26 Bosch Security Systems 7 05 35114F Notes ...
Page 30: ...2000 Series Program Entry Guide 8 0 Bell EN 30 Bosch Security Systems 7 05 35114F Notes ...
Page 58: ...2000 Series Program Entry Guide 14 0 User Test EN 58 Bosch Security Systems 7 05 35114F Notes ...