Security Functions
3–8
1070 073 822-104 (02.06) GB
Disable Auto Power Off
This option disables both the USP monitoring function and the power-off
delay for the power supply:
D
A voltage interruption will cause the PC to shut down immediately.
D
After a normal shutdown, the wait interval of approx. 60 seconds prior to
the shutdown of the power supply is omitted.
Although this function reduces the wait times during startups and software
installations, it must always be disabled during standard operation!
CAUTION
Loss of data!
Activation of this checkbox no longer makes a safe shutdown poss-
ible in the event of a power failure. The device switches off instantly!
Info
Shutdown Count
The displayed value shows how often the system was shut down by UPS, i.e.
how many charging cycles the battery has been subjected to. More details
regarding after how many charging cycles it is necessaary to replace the re-
chargebale batteries is contained in section 8.2.3.
UPS
plus
Mode
There are two operating modes for the UPS
plus
program:
Run as Service
The program is started as part of the Windows 95 startup, and remains active
until Windows 95 is again terminated. Changing user logins have no influ-
ence on the program’s characteristics.
The user in unable to stop the program or terminate monitoring. Although he
would be able to access the active program via the Setup dialog and change
parameter values, these changes would not take effect until Windows 95 has
been restarted.
Run as User Task
The program is started as part of a user login routine, and is terminated upon
logout. The user has full control over all UPS program functions.
Default button
Selecting this button returns all settings to their default values.
These are:
D
COM port:
COM4
D
Smart Shutdown, Delay Time:
50 sec
D
Enable Accu Test:
enabled
D
Enable Temp Control:
enabled
D
Disable Auto Power Off:
disabled
D
Run UPS
plus
as Service:
enabled
Summary of Contents for IPC
Page 1: ...Antriebs und Steuerungstechnik IPC IPC300 Connectivity Manual Industrial PC 104 Edition ...
Page 12: ...Safety Instructions 1 8 1070 073 822 104 02 06 GB Notes ...
Page 18: ...IPC System Overview 2 6 1070 073 822 104 02 06 GB Notes ...
Page 70: ...Interfaces Ports Connectors 6 22 1070 073 822 104 02 06 GB Notes ...
Page 72: ...LED Display 7 2 1070 073 822 104 02 06 GB Notes ...
Page 75: ...Maintenance and Replacement 8 3 1070 073 822 104 02 06 GB IPC300 Fuse ...
Page 88: ...Maintenance and Replacement 8 16 1070 073 822 104 02 06 GB Notes ...