X. Questions and answers

During operation of the device, the temperature indicated on the external thermometer is 

higher than set on the thermostat.

When working in an empty chamber, the air stream passes through the centre where the 

tip of the thermometer is located. Temperatures should be the same when working with the 

charge,  which  causes  mixing  of  warm  air  and  its  even  distribution  in  the  whole  chamber. 

Temperature differences may also be affected by atmospheric conditions.

The thermostat has turned off, the temperature in the chamber is still increasing.

The temperature in the chamber increases after turning off the thermostat due to inertia.

So the heating element releases heat accumulated in itself after turning off for a certain time. 

For stable operation of the device, it is recommended to place a bowl with water under the 

generator burner. This improves the temperature stability inside the chamber.

The chips burn on the smoke generator burner.

Do  not  connect  the  smoker  chimney  outlet  to  chimneys,  ventilation  shafts  or  other 

extensions of the smoke outlet due to the possibility of producing draft in the smoker, which 

can  cause  wood  chips  to  ignite.  The  only  way  that  is  acceptable  for  extending  the  smoke 

outlet, is to apply a hood over the smoker so that smoke can be extracted from the smoker at 

its own speed.

Igniting wood chips may cause accumulated carbon deposit on the feeder and unfavourable 

weather conditions (e.g. wind gusts). Both these factors should be eliminated by removing the 

carbon deposit and protecting the smoker from the gusts of wind or covering the air inlet 

under the smoke generator.

Smoke is led outside at the bottom of the smoker or through the smoke generator.

  The chimney is too closed, it should be tilted enough to let the smoke come out only 

through it.

There is no smoke escaping from the chimney.

No smoke is a sign that a flame has appeared on the smoke generator. Stop the smoke 

generator immediately and put out the flame. The reason for this phenomenon may be the 

connection of the smoker to chimney flues or gusts of wind.

Summary of Contents for BBD-150

Page 1: ...g the device read the instructions MANUAL FOR SMOKERS BBD 70 BBD 150 BBDS 70 BBDS 150 UWD 70 UWD 150 UWDS 70 UWDS 150 SMOKE GENERATOR GD 01 GDS 01 I Safety requirements and precautions II Terms of use III Technical parameters IV Composition of the set V Construction and description of the operation VI Operation of the electronic control panel VII Assembly and installation VIII First start IX Maint...

Page 2: ...Page 2 Dear user Thank you for choosing the Borniak device ...

Page 3: ...should be labelled for outdoor use Power cords of the device should be arranged in such a way that they are not in contact with hot parts of the housing The smoker is intended for outdoor use but it must not be exposed to atmospheric precipitation and strong gusts of wind The optimal solution is to work in roofed sheltered and at the same time ventilated places Do not use the device in closed room...

Page 4: ...urer may result in injury or damage to the device for which the manufacturer is not responsible Be careful with sharp edges when assembling and disassembling the device Do not use the device contrary to its intended use The device is intended for home use Do not leave the device switched on after finishing smoking The device should be inaccessible to animals Do not allow children to use the device...

Page 5: ...dren or animals Do not touch hot components to avoid burns it is recommended to use gloves protecting against high temperature Do not use the packaging to cover the device It is mandatory to connect the device to a grounded electrical outlet an extension cord Protect against rain and water access After each use switch off the device from mains power supply if it is not used Thoroughly clean the sm...

Page 6: ...apacity 70L 70L 150L 150L 2L Maximum temperature 120 C 150 C 120 C 150 C The Degree of the housing tightness IP20 TECHNICAL PARAMETERS OF THE SMOKER Width mm 440 540 625 530 630 715 355 Depth mm 350 400 475 520 180 Hheight mm 820 1040 991 1211 250 OVERALL DIMENSIONS EXTERNAL Width mm 400 490 Depth mm 300 420 Height mm 580 755 DIMENSIONS OF THE CHAMBER INTERNAL dimensions of a smoker assembled with...

Page 7: ...ter bowl 2 pcs A chimney with an air damper Illustrative drawings do not reflect the actual dimensions of the parts the plug type depends on the distribution country type of product and quantity dependent on the set Power cord EU C13 GN tray only BBQ version Crossbars for hanging 3 pcs A 10 1 A A cover for the generator Power cord C13 C14 Wood chips A chimney with an air damper Smoker rack Smoker ...

Page 8: ...eeder 7 starts to rotate at the same time the burner 6 begins to heat The feeder uniformly transports chips from the storage tank 2 to the burner where they start to smoulder Smouldering chips are pushed through the entire length of the burner 6 where at the end they fall into a container filled with water 8 9 7 6 4 1 5 3 LEFT RIGHT 2 10 Using a smoker does not require any special skills and the p...

Page 9: ...one is placed under the generator burner the other under the drip tray opening 4 The first bowl is used to extinguish the falling chips the second one is used to collect the juices from smoked meats The ambient temperature and wind have a large impact on the operating conditions of the device In unfavourable atmospheric conditions the chamber heating time may increase It is advisable to use an ind...

Page 10: ...locking plates DIGITAL CONTROL PANEL The panel is used to control the temperature in the chamber We start the smoker with the switch 2 On the controller 1 see p 11 set the desired temperature With the connector 7 the controller controls the burner in the smoker With the switch 3 we activate the smoke generator connected to the outlet 6 4 FRONT BACK LEFT RIGHT 5 6 7 1 2 3 8 ...

Page 11: ...e display 6 from the set temperature to the burner activation frequency in percent e g value 50 means that the burner is on for the same time as it is off FRONT 1 2 3 4 1 SET confirmation button 2 AT setting auto tuning 3 value increase change button 4 value reduction change button 5 PV current temperature in the chamber 6 SV set temperature frequency of the burner activation CONTROLLER DISPLAY 6 ...

Page 12: ...tallation 1 After taking out of the carton remove unnecessary packaging and elements protecting the product and read the instructions 2 Screw two handles to carry the device 3 Screw the handle to open the door Wsunąć sunąć Wsunąć ...

Page 13: ...moker Tilt the generator slightly to put it on the latches 6 Insert the chimney into the hole at the top of the smoker Pay attention to the correct position of the throttle valve 7 Insert the condenser under the chimney 8 Insert the drip tray onto the bottom rack 9 Mount the electronic control panel see the description p 14 Wsunąć Wkręci N a ło ż y ć i z a c z e p ić Wsunąć Wkręcić Wsunąć i dokręc...

Page 14: ...ry 2 4 hours Connect the generator and the smoker to 230V mains with protective grounding Switch to start the smoke generator and the smoking unit on the electronic panel set the temperature to approx 80 C see Operation of the electronic control panel Heat the smoker for about 2 hours This will reduce technological odours and ensure initial flavouring of the device After heating you can start the ...

Page 15: ...wipe them gently with a damp cloth The shutter and the bowl in which fat and ash are collected must be kept clean because excess fat may ignite NOTE When smoking excess fat falling very fat products control on the shutter it must be removed unconditionally NOTE During the operation of the device carbon deposit forms on the part of the sawdust feeder It should be removed after 8 hours of the genera...

Page 16: ...the smoke generator burner Do not connect the smoker chimney outlet to chimneys ventilation shafts or other extensions of the smoke outlet due to the possibility of producing draft in the smoker which can cause wood chips to ignite The only way that is acceptable for extending the smoke outlet is to apply a hood over the smoker so that smoke can be extracted from the smoker at its own speed Igniti...

Page 17: ...ies in its original packaging 6 When sending in your defective appliance for service a valid Warranty Card without any traces of changes or interference must be included 7 Damage resulting from events such as lightning strike power surge in power lines mechanical impacts fires flooding or other uncontrollable events beyond the Seller s control are not covered by this warranty 8 The User shall deli...

Reviews: