13
1. Loosen the baseplate screws A & B and take away base guard system .
2. Press spindle catch (5) in and keep it pressed. At the same time insert two-sprong
wrecch (14) into flange
C
and loosen the router disc by turning the flange
anticlockwise.
3. Remove the router disc. In doing so, ensure that flange
D
does not become
misplaced.
4. Insert the new routing disc and reassemble the appliance by reversing the above
steps. When doing so, tighten flange
C
firmly.
5. Fit base and securely tighten the screw.
Warning! Always use the guard (base guard system).
The guard protects the
operator from broken disc cutter fragments and unintentional contact with the disc cutter.
Dust extraction system
The adapter for the dust extraction system (12) and / or the dust bag (13) must be fitted.